10.8.7.3 PSU replacement
Replacement: To replace the power supply reverse the removal process shown in the previous
section.
Seating: When re-installing the unit, ensure the assembly is securely positioned onto the
locating lugs as this ensures the unit connects with the RDU chassis which acts as a
heatsink.
Earth warning: A warning label attached to the
RDU door notes that the power
supply must NEVER be operated
(switched ON) when it is
mechanically and electrically
disconnected from the RDU and
SK1 of the MISM backplane.
Earth cable: The earth cable from the
common earthing point in the
base of the RDU MUST be
reconnected to the power supply
chassis.
45
-
690
-
0080
-
001 power unit