User's Manual
SBS-900 Shore Based Radar Systems
Chapter 10: Corrective maintenance
KH-1602-2 issue 1: Standard SBS900 Systems Operator & Maintenance Handbook
Page 179 of 240
10.8 SBS-A1-1 Radar Distribution Unit
10.8.1 System part numbing
In addition to the main part number for the system, a number of options can be added to the
Radar Distribution Unit (RDU). These options are identified by a 6-digit Option number
which is added as a suffix to the main part number.
The option code contains a digit for each available option, where:
' 0 = Indicates the option is not required, not fitted or not available.
' 1 = Indicates the option is required or fitted.
' n = Indicates the particular type of option is required or fitted.
SBS-A1-4- 0 0 0 0 0 0
LAN
Interface
SBS-A129
Additional
Analogue
Output Fitted
SBS-A260
Antenna
Motor Drive
Inverter
Option
(see below)
MantaDigital
Interface Kit
SBS-A270
Antenna
Polarisation
Control Kit
SBS-A302
Product
Specific
Option
(see below)
Antenna Motor Drive Inverter Option:
To cater for global and specific customer requirements the RDU can be supplied with one of
three types of motor drive static inverter fitted.
The kits are factory fitted therefore the option needs to be specified with the main order.
Part No. Output voltage
Option
Code
SBS
-
A403
440V Three Phase Inverter Kit
0
SBS
-
A229
220V Single Phase Inverter Kit
1
SBS-A404 220V Three Phase Inverter Kit 2
Product Specific Options:
This code is used for project specific variations to hardware or software and would be
defined in the specification for the system.