User's Manual

Function Parameters
Power Supplies
110V nominal, 220V nominal (50-60Hz) - single phase
115V/380V/440V 3 phase with optional transformer.
Power corruption protected default parameters.
Interfacing
Standard: 8 x NMEA input/output
(RS422/RS232)
Optional: 8 x NMEA input/output
(RS422/RS232)
MantaDigital Control Interface
Inputs: NMEA 0183/IEC 61162-1 E2
DPT (depth)
GGA, GLL, GNS (position)
DTM (datum)
VHW (water speed)
VBW (ground/water speed)
VTG (ground speed/course over ground)
HDT (heading)
ROT (rate of turn)
RSA (rudder sensor angle)
RPM (engine revs)
AIS (automatic identification system)
ZDA (UTC)
Outputs: OSD (Own Ship data)
TTM (target data)
Standard azimuth interface: 4096:1
Remote monitor up to 20m separation
Transceiver - full operation with Mk4/5/6/7/8 "X" band 10 & 25 kW
Mk7/8 "S" band 30 kW
and SharpEye"S" band transceivers
Display/Transceiver separation - up to 60 metres standard
VDR Interface: A WUXGA RGB video output is provided for a VDR or slave display.
Resolution: 520 mm display; 1680 x 1050 pixels: 650 mm display; 1920 x 1200 pixels.
Page 1.32 Issue 5 (Jan 09)
KH2060-1