User's Manual

MI CRO WAVE RA DI A TION LEV ELS.
Measurement of radiation levels were conducted on 10
th
July 2008 at QinetiQ. The
manufacturer’s representative assisted and enabled the antenna rotation to be disabled
and transmission maintained. Test equipment used was a Narda survey meter mod
8718B and an isotropic probe mod 8721 ser no 13003. A table of results is presented
below.
System 100 W/m
2
distance or
power at Antenna face
50 W/m
2
distance
10 W/m
2
distance
25 kW S-Band CTX-A9 with
3.9 m Low profile S-Band Antenna LPA-A3
28.4 W/m
2
- 510 mm
25 kW X-Band CTX-A8-ACAC with
1.3 m Low profile X-Band Antenna LPA-A13
71.7 W/m
2
60 mm 880 mm
SharpEye DTX-A1 with
3.9 m Low profile S-Band Antenna LPA-A3
21.7 W/m
2
- 90 mm
Issue 5 (Jan 09) Page xi
KH2060
Prelims