Datasheet

KELAG Künzli Elektronik AG Telefon +41 (0)44 806 22 00
Ringstrasse 5 Fax +41 (0)44 806 22 08
Ch-8603 Schwerzenbach E-Mail kelag@kelag.ch
Schweiz / Switzerland
www.accelerometer.ch/en
Revision January 2011 We reserve the right to modify this specification without prior notice
1)
Repeatability:
maximum offset
occurring with position change after
return to initial position (corre
sponds
to achievable precision, including
temperature hysteresis after
temperature compensation and
linearization).
2) Cross axis sensitivity: maximum
error occurring with (additional)
inclination or acceleration from
another direction than the
measuring plane
3) Supply stabilized
4) Measuring range: Trigonometric
function:
angle = arcsin
ySensitivit
(Offset) 2,5Vout
(paste values without units)
5) Typical values;
6)
Long term stability: calculated
values from HTB tests. Test results
available at request.
7) Cable
is specified for -15°C for
dynamic and -30°C for static
applications.
Single Axis Acceleration Sensor
KAS901- 04
The sensors are based one an advanced “bulk micro machined” technology. The three dimensional structure of
these sensors comprise a pendulum made of mono crystalline silicon. The pendulum is hermetically enclosed
between two silicon discs. From this construction results a long term stable, high resolution und shock resistant
sensor. A gas damping prevents overshooting and interfering resonance oscillation. An ASIC measures the
capacitive change caused by the movement of the pendulum.
senses in positive and negative direction
static and dynamic acceleration measured
high repeatability up to 0,05% over range
high resolution: up to 0,005% over range
shock resistance of the pendulum min. 50’000g
temperature range -30 .. +85°C
passive temperature compensation
small, solid brass housing with fixing holes
rugged PVC cable
large output span: 0.5 .. 4.5V output over measuring range
power supply requirement: 7... 36 VDC, stabilized
red
brown
orange
black
+7... 36VDC
Out X
Out Y
0V
Shield/Housing
Fixing holes for M3 cylinder head screws
Outputs have no protection
against polarity reversal
Height 12mm
27.0
8.0
35.0
25.0
060721-9011011
X
KAS901-xxX
Inclination
Y
Parameter Conditions
KAS901-04
Unit
Measuring range
4)
+/- 1,7
+/- 90
G
°
Repeatability at 0°
(horizontal position)
1)
at 0...40°C,
20°C typ
4
0,2
mg
°
Resolution at 0° / 1g DC .. 1Hz 0,2
0,01
mg
°
typ. Offset temperature
dependency
20...60°C 0.6 mg/°
long term stability
6)
10 years
6)
approx. 1,5 mg
Measuring direction x-axis
Cross axis sensitivity
2)
4 %
damping -3 dB 50 Hz
5)
Operating temperature range -30
7)
.. +85 °C
Shock resistance (Chip) 20’000 g
Output signal V
out
Offset = V
out
in 0°/1gposition
Sensitivity
0,5 .. 4,5
2,5
4
V
V
V/g
Power supply
3)
7... 36 VDC
Other versions
:
single and dual axis sensors in IP67
housing with cable or connector and
standardized output 4... 20mA, 2...10V and
Modbus
smaller cases and sensors for higher
temperatures ranges