Datasheet

Series 2200 rear panel.
DC POWER SUPPLIES
www.keithley.com
1.888.KEITHLEY
(U.S. only)
A Greater Measure of Confidence
Series 2200
Single-Channel Programmable
DC Power Supplies
2200-20-5 2200-30-5 2200-32-3 2200-60-2 2200-72-1
DC OUTPUT RATING
Voltage
0 to 20 V 0 to 30 V 0 to 32 V 0 to 60 V 0 to 72 V
Current
0 to 5 A 0 to 5 A 0 to 3 A 0 to 2.5 A 0 to 1.2 A
MAXIMUM POWER
100 W 150 W 96 W 150 W 86 W
LOAD REGULATION
Voltage
<0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV
Current
<0.05% + 0.1 mA <0.05% + 1.5 mA <0.05% + 0.1 mA <0.05% + 0.5 mA <0.05% + 0.5 mA
LINE REGULATION
Voltage
< 0.01% + 1 mV <0.01% + 1 mV <0.01% + 1 mV <0.01% + 2 mV <0.01% + 1 mV
Current
<0.05% + 0.1 mA <0.05% + 0.1 mA <0.05% + 0.1 mA <0.05% + 0.05 mA <0.05% + 0.1 mA
RIPPLE AND NOISE (20 Hz to 7 MHz)
Voltage
<1 mV
RMS
<3 mV
P-P
<1 mV
RMS
<4 mV
P-P
<1 mV
RMS
<4 mV
P-P
<1 mV
RMS
<5 mV
P-P
<1 mV
RMS
<3 mV
P-P
Current
<3 mA
RMS
<4 mA
RMS
<3 mA
RMS
<3 mA
RMS
<3 mA
RMS
SETTING RESOLUTION
Voltage
1 mV 1 mV 1 mV 1 mV 1 mV
Current
0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA
SETTING ACCURACY (using remote sense, 25°C ± 5°C)
Voltage
±0.03% + 3 mV ±0.03% + 3 mV ±0.03% + 3 mV ±0.03% + 6 mV ±0.03% + 6 mV
Current
±0.05% + 2 mA ±0.05% + 2.5 mA ±0.05% + 2 mA ±0.05% + 1.5 mA ±0.05% + 1 mA
READBACK RESOLUTION
Voltage
1 mV 1 mV 1 mV 1 mV 1 mV
Current
0.1 mA 0.1 mA 0.1 mA 0.1 mA 0.1 mA
READBACK ACCURACY (25°C ± 5°C)
Voltage
0.02% + 3 mV ±0.02% + 2.5 mV ±0.02% + 3 mV ±0.02% + 6 mV ±0.02% + 5 mV
Current
±0.05% + 2 mA ±0.05% + 2.5 mA ±0.05% + 2 mA ±0.05% + 1.5 mA ±0.05% + 1 mA
VOLTAGE TRANSIENT RESPONSE – SETTLING TIME
Load Change
<400 µs to within 75 mV following a change from 0.1 A to 1A
Setting Change
Rising
<35 ms from beginning of excursion to within 75 mV of terminal value following a change from 1 V to 11 V with a 1 A load
(Note: Specification does not include command decode time)
Falling
<35 ms from beginning of excursion to within 75 mV of terminal value following a change from 11 V to 1 V with a 1 A load
(Note: Specification does not include command decode time)
OVERVOLTAGE PROTECTION
Range (typical)
1 V to 19 V 1 V to 29 V 1 V to 31 V 1 V to 59 V 1 V to 71 V
Accuracy
±0.5% + 0.5 V ±0.5% + 0.5 V ±0.5% + 0.5 V ±0.5% + 0.5 V ±0.5% + 0.5 V
Response Time (typical)
<10 ms <10 ms <10 ms <10 ms <10 ms