AIR250 ABDOMINAL OPERATION MANUAL CONTENTS 02 03 — GENERAL INFORMATION 03_INTRODUCTION 03_REGISTER YOUR PURCHASE 03_SERIAL NUMBER INFORMATION 04 — IMPORTANT SAFETY INFORMATION 06 — TECHNICAL SPECIFICATIONS 06_EQUIPMENT SPECIFICATIONS 06_TECHNICAL DATA 07 — INSTALLATION AND PLACEMENT 07_TRAINING SPACE 08 — OPERATION 08_EQUIPMENT OVERVIEW 09_POWER DISPLAY 10_DISPLAY FEATURES 11_PROPER OPERATION CHECK 12_HOW TO USE THE AIR250 ABDOMINAL 14_POWER TEST 15 — MAINTENANCE 15_PREVENTATIVE MAINTENANCE SCHEDULE
AIR250 ABDOMINAL OPERATION MANUAL 03 GENERAL INFORMATION INTRODUCTION Congratulations on the purchase of your new Keiser Air250 Abdominal and welcome to the Keiser family. Keiser’s Dynamic Variable Resistance safely builds strength at any speed, which is key to building maximum power. For your safety, and to ensure the best experience and maximum gains, it is critical that you read and understand this manual before you begin using the Air250 Abdominal.
AIR250 ABDOMINAL OPERATION MANUAL 04 IMPORTANT SAFETY INFORMATION It is the sole responsibility of the purchaser of Keiser Corporation equipment to instruct all individuals, whether they are the enduser or supervising personnel, on proper usage of the equipment. Keiser Corporation recommends that all users of its equipment be informed of the following information before use. 1. Read these instructions. 2. Heed all warnings. 3. Follow these instructions. 4.
AIR250 ABDOMINAL OPERATION MANUAL 05 IMPORTANT SAFETY INFORMATION (CONTINUED) CONVENTIONS USED This Operation Manual contains the following marks: WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION: Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury. IMPORTANT: Indicates information considered critical, but not hazard-related.
AIR250 ABDOMINAL OPERATION MANUAL 06 TECHNICAL SPECIFICATIONS EQUIPMENT SPECIFICATIONS See Figure 2 for Air250 Abdominal dimensions and weight. • Resistance Range 0 – 276 lbs (0 – 125 kg) change resistance in 1 lb/kg increments • Adjustable Seat • Maximum user weight limit: 441 lbs (200 kg) 47 inches (1,194 mm) 33 inches (838 mm) 37 inches (940 mm) 115 lbs (52 kg) Figure 2.
AIR250 ABDOMINAL OPERATION MANUAL 07 INSTALLATION AND PLACEMENT No assembly required. Place the Air250 Abdominal on a flat, level surface. Make sure the base of the frame makes full contact with the floor. If gaps are present, relocate the equipment to an even surface. CONNECT THE EQUIPMENT TO THE KEISER AIR SYSTEM Keiser Air System (floor or wall air outlet) WARNING: Never connect equipment to an air source capable of exceeding 120 psi / 8.27 bar.
AIR250 ABDOMINAL OPERATION MANUAL 08 OPERATION EQUIPMENT OVERVIEW 1 12 2 11 10 9 3 4 8 7 6 5 Figure 5.
AIR250 ABDOMINAL OPERATION MANUAL 09 POWER DISPLAY 1 2 3 4 6 5 SEAT 7 8 When using the eChip, ensure that it is fully inserted into the slot as shown. Figure 6. Power Display Overview CAUTION Rate monitoring systems may be inaccurate. Over exercising may result in serious injury or death. If you feel faint stop exercising immediately. “Peak Power” not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
AIR250 ABDOMINAL OPERATION MANUAL 10 DISPLAY FEATURES LINE 1 - RESISTANCE The Resistance window displays the current resistance or OFF. Adjust the resistance using the (+/-) Thumb Buttons located on the Handles. When the window displays OFF, the machine enters a low power consumption sleep mode to increase battery life. Normal operation may be resumed by pressing either Thumb Button or by inserting the eChip.
AIR250 ABDOMINAL OPERATION MANUAL 11 PROPER OPERATION CHECK Check equipment condition and function before every workout: A. Thumb Buttons and Display — press Thumb Buttons to check for proper “+ / -” operation and the Display powers on*. D. Seat Adjustment — Seat functions and engages into setting positions properly; Locking Pin engages properly into the post. B. Exercise Arm — move freely; no loose parts in the linkage system. E. Stability — equipment is level to a solid, flat surface. F.
AIR250 ABDOMINAL OPERATION MANUAL HOW TO USE THE AIR250 ABDOMINAL 1.1 Adjust the Seat height to allow the Chest Pads to rest firmly against your upper chest. 2. Sit with your back supported by the Seat backrest, feet on the floor (or on the Anti-Slip Step). 2 3. Grasp the Handles with an underhand grip and adjust the resistance with the Thumb Buttons. 3 4. Curl your upper body forward; return slowly. 4 ADJUST EXERCISE Seat Locking Pin Figure 8.
AIR250 ABDOMINAL OPERATION MANUAL 13 HOW TO USE THE AIR250 ABDOMINAL (CONTINUED) CAUTION • • • • Consult your physician before beginning any exercise program. This equipment should only be used with proper instructions. Proper warm-up required to help prevent serious injury. Always maintain good form and control during exercise. • • • If you feel pain, faintness, or are unable to maintain good form, stop immediately. Use caution when increasing/decreasing resistance during exercise.
AIR250 ABDOMINAL OPERATION MANUAL 14 POWER TEST CAUTION • • • • Test should only be performed with proper instruction. Never perform Power Test without proper warm-up. Always maintain good form and control throughout test. Rate monitoring systems may be inaccurate. Over exercising may result in serious injury or death. If you feel faint stop exercising immediately.
AIR250 ABDOMINAL OPERATION MANUAL 15 MAINTENANCE CAUTION: SERVICE AND REPAIR SHALL ONLY BE PERFORMED BY KEISER-CERTIFIED TECHNICIANS. Failure to follow these instructions can result in serious injury. PREVENTATIVE MAINTENANCE SCHEDULE CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS REGULARLY INSPECTED FOR DAMAGE AND WEAR. Immediately replace damaged, worn, or broken parts.
AIR250 ABDOMINAL OPERATION MANUAL 16 BATTERY REPLACEMENT Do not operate the equipment during battery replacement procedure. “Lo-bA” = Batteries are low, replace immediately. NOTE: If batteries are dead (depleted), the Power Display remains blank. To replace the batteries, refer to Figure 10 and follow the instructions below (no tools required). 1. Unscrew the Brass Nut on the Processor Box. Pull and remove the cover. 2.
AIR250 ABDOMINAL OPERATION MANUAL 17 ANNUAL MAINTENANCE The following routine maintenance is recommended annually or at the time batteries are replaced: 1.1 Clean: • Wipe any accumulated dust around the Frame and the Linkage System, including the Air Tank and Cylinder, using a clean shop cloth. 2 2. Visual inspection of the Linkage System: • Move freely and no loose parts; all externally visible nuts and bolts are tightened properly. 3 3.
AIR250 ABDOMINAL OPERATION MANUAL 18 REGULATORY AND COMPLIANCE NOTICES Standards ISO/EN 20957-1 Accuracy Class A (High accuracy) and Usage Class S (Studio, commercial use); IEC/EN 60601-1 and IEC/EN 60601-1-2. Marks SAFETY NOTIFICATIONS Displayed watts testing parameters: “Current Power,” “Peak Power,” and “Percent of Peak Power” are not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
AIR250 ABDOMINAL OPERATION MANUAL 19 ELECTROMAGNETIC COMPATIBILITY (EMC) EMC Notices — Statement of Compliance This product has been determined to be compliant with the applicable standards, regulations, and directives for the countries where the product is marketed. Compliance documentation, such as Declaration of Compliance for the product, are available upon request by contacting service@keiser.com.
AIR250 ABDOMINAL OPERATION MANUAL 20 WARRANTY STATEMENT View or print your Air250 Abdominal warranty online at keiser.com/support/warranty. If you have any questions about your warranty, please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at service@keiser.com.