Instruction Manual

1030 | 1031 LARGE AIR COMPRESSOR
09
Error Code Description/Symptoms Probable Cause Solution
E r 6
Motor START signal was not
received by the Computer
Control System (CCS).
NOTE: The motor may
have been given a signal to
start, however no pressure
increase was detected in
the Purge Tank.
Major air leak in the system. Check compressor hoses and
ttings for leaks; connect
exercise machines to the
compressor one at a time to
check for leaks (see leak check
procedure in the “Solution”
column for E r 2, E r 8)
Motor failure or Start
circuit failure.
Disconnect, then reconnect the
compressor to power supply.
Listen for the motor start and
the Solenoid Valve click:
If the motor runs then
check plumbing to
ensure that all hoses are
connected.
If the motor does not start
and the Solenoid Valve
clicks, the motor is faulty
and must be replaced.
If the motor does not start
and the Solenoid Valve
does not click, the Circuit
Board is faulty and must be
replaced.
E r 7
Insufcient/no pressure
build in Air Tanks.
Major air leak in one of the
exercise machines or in the
compressor plumbing.
Check compressor hoses and
ttings for leaks; connect
exercise machines to the
compressor one at a time to
check for leaks (see leak check
procedure in the “Solution”
column for E r 2, E r 8)
E r 9
Air pressure building too
slow.
Dirty or blocked Inlet-
Mufer Assembly.
Ensure the compressor located
in a clean, dry, and well-
ventilated area; vents are not
blocked. Replace Inlet-Mufer
Assembly.
E r 10
Formerly “E r A”
1030X, 1031X models only
Communication failure
between the two computer
Circuit Boards.
Damaged Communication
Cable.
Replace the Communication
Cable.
Circuit Board failure.
NOTE: Either Circuit Board
can cause itself or the
other to display the error.
Replace the Circuit Board(s).
E r 11
Purge Valve leak detected. Loose hose/tting, o-ring
failure, or loose canister.
Check for loose hose/tting;
ensure the o-ring is not
damaged/torn and canister is
threaded properly and snug on
the bushing.