Instruction Manual

1030 | 1031 LARGE AIR COMPRESSOR
07
1. Power ON: Plug the power cord to the appropriate power
supply to power ON the air compressor.
The air compressor is not equipped with a power ON/OFF
switch. Power is controlled by the power cord plugged at
the electrical outlet.
The air compressor software is factory preset to shut off
the motors at 118–120 psig (8.14–8.27 bar) and to re-start
at 97 ±5 psig (6.69 ±0.34 bar).
2. Power OFF: The air compressor is designed to remain in
the power ON condition. There is no need to power OFF
the air compressor, other than for care and maintenance
purposes (see the Care and Maintenance section below
for complete instructions).
Clean the air compressor exterior with a soft brush or wipe
with a moistened cloth using only water and mild soap.
Wipe dry the air compressor.
Do not use cleaning solvents as they can be toxic and
ammable.
Always keep parts clean from dirt and dust for optimal
equipment performance.
Lubrication: The motors are oil-less and require no
lubrication.
Drain Tube with Foam: Check the foam for tears, damage or
excessive wear. If worn, damaged, or missing, Contact Keiser
Customer Support for replacement.
Inspect: Periodically inspect the air compressor for damaged,
worn, or broken parts; check for normal operating sounds and
any error codes. Make note of any error code and contact
Keiser Customer Support for service and corrective action.
All repairs and maintenance shall only be performed by Keiser-
certied technicians. Do not open any parts or components
of the air compressor or attempt to resolve any issue on
your own. Only use replacement parts recommended by Keiser
Corporation.
Make sure all connections are tight. Do not overtighten. Any
leaks at hose or pipe connections will diminish air compressor
performance.
To test for leaks, spray a small amount of soapy water on the
area suspected of leaking. If the soap bubbles, try tightening
the connection or replace the broken part. Do not install
used compression nuts. Do not use the air compressor until all
repairs have been completed and tested by a Keiser-certied
technician.
1. Disconnect the power cord to power OFF, and wrap the
power cord around the air compressor handle to reduce
the risk of damage.
2. Close the shut-off valve.
3. Disconnect the 1/2-inch air line at the air compressor.
4. Open the shut-off valve slowly to release all air pressure
in the air tank.
5. Clean the air compressor to remove all dirt and dust.
6. Place a cover over the air compressor to protect the unit
from dust and moisture.
7. Do not stack or store any items on top of or around the
air compressor.
8. Store indoors.
DAILY OPERATION
CARE AND MAINTENANCE
CAUTION
HOT SURFACE
Before cleaning the air compressor:
1. Disconnect the power cord from the power supply.
2. Allow the air compressor to cool down.
CLEANING
MAINTENANCE
TEST FOR LEAKS
STORAGE