5.2 Calibration 5.2
Calibrating the Measuring scales
The two horizontal squaring arm scales are already attached to the machine but may not
be positioned accurately and will need calibrating.
Horizontal scales: The SteelTrak can be loaded from either side and the scales are
used by eye or using the stops to measure the required width of board that will be cut
off to the left or right of the cut line. the cutting blade, twin wheels and scoring tools cut
on the same line. the measuring scales are fixed to sliding stainless steel strips that can
be moved to allow accurate calibration.
1. Slide the two Measuring Stops onto the Squaring Arm being careful to align the pro
file of the stop and its locking bar to the profile of the Squaring Arm. The Measuring
Stops are able to 'flip' in and out as required.
2. Set both stops at 15cm (6"), 'flip' one of the stops into place and the other out, then
place a piece of card in the machine and slide it to touch the stop that is flipped in.
Clamp the card in place select the cutting blade on the rotating cutter head and cut
the card.
3. Measure the cut width of the card, say it is 14.7cm (5 7/8"), slide the Measuring Scale
so that it reads the dimension measured i.e. 14.7cm (5 7/8"). Repeat the process
with the other Measuring Stop.
NOTE: If the scales move too freely it is simple to increase the friction. To avoid reset-
ting the scales first choose any easily remembered dimension and set the stop. Slide the
scale from its groove, twist it and replace it to the remembered dimension.