Technical Description

RFID-Module Technical specification
10 Technical specification
General
Reading distance: 4 cm from the front panel
Antenna installation: permanently installed in the front panel
Positioning of XE 020/A RFID module:
evaluation unit can be located up to 30 cm from
antenna
Communication protocol:
according to ISO 15693 or ISO 18000-3,
and suitable for Euromap 65
Evaluation unit protection class: IP 20
XE 020/A RFID module contact protection: metal case
XE 020/ANT antenna module contact protection: Plastic case
Signalling: 3-colour LED on the printed antenna
Interfaces
Data interface: serial
Supply voltage: 12 V DC (+/- 5%)
Connector plug: RJ45
RF signal
Frequency response: 13.56 MHz
Transmission power: 200 mW (max. 250 mW)
Sampling rate:
configurable (default: 10 samples / sec)
Dimensions
Printed antenna width: 57 mm
length: 53 mm
Evaluation unit width: 88 mm (with casing)
length: 64 mm (with casing)
height: 21 mm (with casing)
Environmental conditions
Operating temperature: +5 °C to +55 °C
Storage temperature: -30 °C to +70 °C
Relative humidity: 5 to 95% (non-condensing)
Vibration resistance: as per IEC 61131
Shock resistance: as per IEC 61131