TABLE 4 – DRIVE OPERATING CONDITION & STATUS LED INDICATOR
LED Drive Status
Color and
Flash Sequence Flash Rate
Color and Sequence
4
After Recovered Fault
ST
(Status)
Normal Operation (Run) Green 1 Sec. On / Off
Overload (120% – 160% Full Load) Red On Continuously Green
I
2
t (Drive Timed Out) Red 0.25 Sec. On / Off
Short Circuit Red 1 Sec. On / Off
Undervoltage Red / Yellow 0.25 Sec. On / Off Red / Yellow / Green
5
Overvoltage Red / Yellow 1 Sec. On / Off Red / Yellow / Green
5
Stop Yellow On Continuously
Phase Loss Detection
1,2
Yellow 0.04 Sec. On / 0.06 Sec. Off
Communication Error
3
Green / Red 1 Sec. On / Off Green
PWR
(Power)
Buss and Logic Power Supply Green On Continuously
Notes: 1. Phase Loss Detection: Models KBVF-23P, 24P, 29, 45, 48. 2. Requires AC line restart. 3. With DIVF Modbus
Communication Module Installed. 4. All LED flash rates, after recovered faults, are 1 Sec. On / Off. 5. Drive will require
manual restart to return the Status LED color to its normal flashing green.
12 DIAGNOSTIC LEDS
The drive contains two diagnostic LEDs to display the drive’s operational status. See Figure 4, on
page 20, for the location of the “PWR” and “ST” LEDs.