User Guide

7
ARM
FUSE
A
TB3
M1
M2
L2
L1
AC
LINE
GROUND
(earth)
ARM
MOTOR
E
F
U
SS
E
F
U
F1
FIG. 6 – AC LINE AND
ARMATURE CONNECTION
A. AC Line – Connect AC Line to terminals L1 and
L2. (Be sure jumpers J1 and J2 are set to match
the AC Line voltage used.) (See table 5, p. 4.)
B. Motor Armature Connect motor armature to
terminal M1 and M2. (Be sure jumper J4 is set to
match motor voltage.) (See table 5, p. 4.)
C. Ground Be sure to ground (earth) control via
green screw located on chassis. Do not ground
any other terminals.
D. Field For Shunt Wound motors only. Do not
use F+ and F- terminals for any other motor type.
Connect motor shunt field to terminals F+ and F-
for 90VDC motors with 100VDC fields and
180VDC motors with 200VDC fields. For motors
with half voltage fields, 90VDC motors with
50VDC fields and 180VDC motors with 100VDC
fields, connect field to terminals F+ and L1. See
table 7 for summary of field connections.
CAUTION – Shunt-Wound motors may be
damaged if field remains powered without
motor rotating for an extended period of time.
L1
L2
A
FIELD
AC
LINE
ARM
TB3
M2
M1
F+ F-
TB2
FUSE
F1
ARM
FIG. 7A – FULL VOLTAGE FIELD
M1
LINE
AC
L1 M2
L2
TB3
A
F+
TB2
F-
FIELD
ARM
FUSE
F1
ARM
FIG. 7B – HALF VOLTAGE FIELD
TABLE 7 – FIELD CONNECTIONS (Shunt Wound Motors Only)
AC Line Voltage (VAC) Motor Voltage Field Voltage (VDC) Field Connection
115 90 100 F+, F-
115 90 50 F+, L1
230 180 200 F+, F-
230 180 100 F+, L1
230 90* 100
F+, L1
*Step Down operation (see sec. III C, p. 4).