Installation Manual

MODEL KBDF-29 (1P) SUPPLEMENT
IMPORTANT: The KBDF Series Installation and Operation Manual (Part No. A40177) must be read
and understood before attempting to operate this drive. For further assistance, contact our Sales
Department at 954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION: Model KBDF-29 (1P) has been added to the KBDF Series of drives. This model is
designed to accept 1-phase 208/230 Volt AC line input only. Table 1 is an addition to the Electrical
Ratings table, on page 15 of the manual. Figure 1 is an addition to Section 8.1 (AC Line and Ground)
of the manual.
WARNING! HIGH VOLTAGE!
DISCONNECT MAIN POWER BEFORE MAKING CONNECTIONS TO THE DRIVE
TABLE 1
ELECTRICAL RATINGS
AC Line Input Output Net Wt.
Model No.
Part
No.
Maximum
Horsepower
(HP (kW))
Volts AC
(50/60 Hz)
Phase (Ф)
Maximum
Current
(Amps AC)
Fuse or
Circuit
Breaker
Rating
(Amps AC)
Maximum
Voltage
(Volts AC)
Maximum
Continuous
Load Current
(RMS Amps/Phase)
lbs kg
Case Size
KBDF-29 (1P) 9700 3 (2.25) 208/230 1 22 25 230 9.0 4.65 2.10 B
FIGURE 1
AC LINE AND GROUND CONNECTIONS
KB Electronics, Inc.
12095 NW 39th Street, Coral Springs, FL 33065-2516 (954) 346-4900 FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 info@kbelectronics.com
www.kbelectronics.com (A40219) – Rev. A00 – 2/17/2014