User's Manual
Table Of Contents
- Appendix B. Regulatory Compliance and Agency Approvals
- Chapter 1. Kaye ValProbe RT System
- Chapter 2. Kaye ValProbe RT Hardware
- Chapter 3. ValProbe RT System Connections
- Chapter 4. Creating User Accounts
- Chapter 5. Defining Equipment
- Chapter 6. Defining Assets
- Chapter 7. Defining Study Setups
- Chapter 8. Viewing Live Data
- Chapter 9. Qualification Study
- Chapter 10. Sensor Verification
- Chapter 11. Qualification Reports
- Appendix A. Specifications
- A.1 Kaye ValProbe RT System
- A.1.1 List of Certified Countries
- A.1.2 Regulatory Compliance
- A.1.3 RF System Operating Frequency and Modulation
- A.1.4 RF Channels
- A.1.5 RF Network Topology and PAN ID (Network ID)
- A.1.6 Antenna Diversity
- A.1.7 Data Rate and Data Encryption
- A.1.8 RF Range (Line of Sight and Outdoor)
- A.1.9 Number of Loggers and Sensors Supported
- A.1.10 Sensor Sampling Rate
- A.1.11 Data Transmission Rate
- A.1.12 Sensor Samples Data Storage Capacity
- A.1.13 Optional Extendable Base Station Antenna
- A.2 Kaye ValProbe RT Base Station
- A.2.1 Input Power and Adaptor Ratings
- A.2.2 Installation Category
- A.2.3 Overvoltage Category and Electrical Safety Protection Class
- A.2.4 Input DC Power On/Off Switch
- A.2.5 Front Panel LED Indications and Buzzer
- A.2.6 Bath and IRTD Interface Ports
- A.2.7 USB Port
- A.2.8 Ethernet Communication Port
- A.2.9 Reset Switch to Reload Default Factory Settings
- A.2.10 Wakeup Magnet
- A.2.11 Batteries
- A.2.12 Unit Dimensions
- A.2.13 Enclosure Material
- A.2.14 Environmental Ratings
- A.3 Kaye ValProbe RT Logger
- A.3.1 Installation Category
- A.3.2 Overvoltage Category and Electrical Safety Protection Class
- A.3.3 Magnetic Switch
- A.3.4 LED Indications
- A.3.5 Calibration
- A.3.6 Real Time Clock Accuracy
- A.3.7 Sensing Elements
- A.3.8 Housing Material
- A.3.9 Logger Base Dimensions
- A.3.10 Ingress Protection
- A.3.11 Insulating Canister X2545
- A.3.12 Battery
- A.3.13 Shelf Life
- A.3.14 Battery Life
- A.4.1 Measurement Accuracy
- A.4.2 Body Environmental Ratings:
- A.4.3 Number of Input Channels
- A.4.4 Sensor Types and Measurement Range
- A.4.5 Sensor Lengths
- A.5.1 Measurement Accuracy
- A.5.2 Body Environmental ratings:
- A.5.3 Number of Input Channels
- A.5.4 Sensor Types and Measurement Range
- A.5.5 Sensor Lengths
- A.6.1 Measurement Accuracy
- A.1 Kaye ValProbe RT System
- Appendix B. Regulatory Compliance and Agency Approvals
- B.1 Electrical Safety Approvals:
- B.2 Radio and EMC Certification Approvals:
- B.3 Ingress Protection for Kaye ValProbe RT Logger
- B.4 United States FDA 21 CFR Part 11 Complaint Software Application
- B.5 Transportation Regulations
- B.6 FCC Compliance Statement
- B.7 ISED Canada Compliance Statement
- B.8 EU Compliance Statement:
- B.9
- Product Certification Labels
- Appendix C. Environnemental Compliance
- Appendix D. Warranty and Returns:
- Appendix E. Service Information
Chapter 8: Viewing Live Data
Kaye ValProbe RT User Manual 77
Historical Data View
The ValProbe RT stores the data of the current study in its internal memory. In addition to the
real-time data view it is possible to review this historical data anytime during a study.
When connecting to a ValProbe RT that runs a qualification study, when switching to the
Graph View, a progress indicator represents the download of the data to the console.
When finished, below the graph there are additional controls available to access historical
data:
The historical data is represented by the chunks displayed with the timestamp the data was
recorded. The size of the chunks can be set in the dropdown to display 1, 2, 4, 6, 12, and 24
hours duration. If such a chunk is selected the graph automatically switches to the historical
mode.
Following functions are available in historical mode:
• The headline of the graph changes from Real-Time data to Historical data
• The zoom allows to zoom and navigate inside the displayed chunk
• The groups selection works like in real-time view, only the selected group and
corresponding calculations are displayed.
• The manual scale button is extended to the scale the X-axis to set the displayed
time.
• You can directly display a data chunk by selecting it.
• A line in the Graph can be used to navigate to any timestamp in the graph and see
the time and calculation data displayed for that specific timestamp.
• When selecting the “Sensor Value in table” checkbox the calculation window is
replaced by the sensor readings for the timestamp selected with the selection line.
• With the arrow buttons, it is possible to navigate from data chunk to data chunk.
• The double arrow on the left will jump directly to the first data chunk.
• The double arrow on the right will jump back to the live data screen and the
headline of the graph displays Real-Time data again.
On reconnect to a console, the ValProbe RT displays real-time data, while historical data is
downloaded automatically to the console for review. The download of historical data is
indicated by a progress cycle.