User's Manual
Table Of Contents
- Appendix B. Regulatory Compliance and Agency Approvals
- Chapter 1. Kaye ValProbe RT System
- Chapter 2. Kaye ValProbe RT Hardware
- Chapter 3. ValProbe RT System Connections
- Chapter 4. Creating User Accounts
- Chapter 5. Defining Equipment
- Chapter 6. Defining Assets
- Chapter 7. Defining Study Setups
- Chapter 8. Viewing Live Data
- Chapter 9. Qualification Study
- Chapter 10. Sensor Verification
- Chapter 11. Qualification Reports
- Appendix A. Specifications
- A.1 Kaye ValProbe RT System
- A.1.1 List of Certified Countries
- A.1.2 Regulatory Compliance
- A.1.3 RF System Operating Frequency and Modulation
- A.1.4 RF Channels
- A.1.5 RF Network Topology and PAN ID (Network ID)
- A.1.6 Antenna Diversity
- A.1.7 Data Rate and Data Encryption
- A.1.8 RF Range (Line of Sight and Outdoor)
- A.1.9 Number of Loggers and Sensors Supported
- A.1.10 Sensor Sampling Rate
- A.1.11 Data Transmission Rate
- A.1.12 Sensor Samples Data Storage Capacity
- A.1.13 Optional Extendable Base Station Antenna
- A.2 Kaye ValProbe RT Base Station
- A.2.1 Input Power and Adaptor Ratings
- A.2.2 Installation Category
- A.2.3 Overvoltage Category and Electrical Safety Protection Class
- A.2.4 Input DC Power On/Off Switch
- A.2.5 Front Panel LED Indications and Buzzer
- A.2.6 Bath and IRTD Interface Ports
- A.2.7 USB Port
- A.2.8 Ethernet Communication Port
- A.2.9 Reset Switch to Reload Default Factory Settings
- A.2.10 Wakeup Magnet
- A.2.11 Batteries
- A.2.12 Unit Dimensions
- A.2.13 Enclosure Material
- A.2.14 Environmental Ratings
- A.3 Kaye ValProbe RT Logger
- A.3.1 Installation Category
- A.3.2 Overvoltage Category and Electrical Safety Protection Class
- A.3.3 Magnetic Switch
- A.3.4 LED Indications
- A.3.5 Calibration
- A.3.6 Real Time Clock Accuracy
- A.3.7 Sensing Elements
- A.3.8 Housing Material
- A.3.9 Logger Base Dimensions
- A.3.10 Ingress Protection
- A.3.11 Insulating Canister X2545
- A.3.12 Battery
- A.3.13 Shelf Life
- A.3.14 Battery Life
- A.4.1 Measurement Accuracy
- A.4.2 Body Environmental Ratings:
- A.4.3 Number of Input Channels
- A.4.4 Sensor Types and Measurement Range
- A.4.5 Sensor Lengths
- A.5.1 Measurement Accuracy
- A.5.2 Body Environmental ratings:
- A.5.3 Number of Input Channels
- A.5.4 Sensor Types and Measurement Range
- A.5.5 Sensor Lengths
- A.6.1 Measurement Accuracy
- A.1 Kaye ValProbe RT System
- Appendix B. Regulatory Compliance and Agency Approvals
- B.1 Electrical Safety Approvals:
- B.2 Radio and EMC Certification Approvals:
- B.3 Ingress Protection for Kaye ValProbe RT Logger
- B.4 United States FDA 21 CFR Part 11 Complaint Software Application
- B.5 Transportation Regulations
- B.6 FCC Compliance Statement
- B.7 ISED Canada Compliance Statement
- B.8 EU Compliance Statement:
- B.9
- Product Certification Labels
- Appendix C. Environnemental Compliance
- Appendix D. Warranty and Returns:
- Appendix E. Service Information
Chapter 11: Qualification Reports
Kaye ValProbe RT User Manual 111
11.7. Pass/Fail Report
Pass / Fail Report Overview
The Pass / Fail Criteria report eliminates hours of manual or spreadsheet based analysis, by
providing an automated report, which analyzes Qualification raw data and provides a report
detailing whether the Qualification data successfully passed or failed to meet user defined
criteria.
To better understand the functionality of the Pass / Fail Criteria report it is important to
understand the details of the following key elements:
• What data from the Qualification raw data file is utilized to perform the Pass / Fail
analysis?
• How are the Pass / Fail Criteria calculations applied?
Qualification Raw Data File
The Qualification raw data file contains all the data captured from the Qualification Start time
to the Qualification End. The amount and content of the data is defined by the user in the
Setup report. The Setup defines the following:
• Number and type of sensors included (i.e. temperature, pressure, )
• Grouping of sensors (Distribution, Penetration, Shelf 1/Shelf 2 etc.)
• Calculations (Statistical, Lethality, Saturation etc.)
• Events triggering: Start and Stop of Qualification, Start and Stop of Exposure
• Any additional events based of defined process conditions
• Sample / Storage Rate of data capture (timestamp interval)
Qualification time stamps and associated data are captured:
• At the time Events occur (i.e. Qualification Start/Stop, Exposure Start/Stop, or
defined process events)
• At user defined intervals based on configuration of the Sample/Storage rate.
Definition of Cycles
The Pass / Fail Criteria report allows the user to define a Cycle during the Qualification study
during which captured process data is analyzed. A cycle is a defined period during the
Qualification study. The ValProbe RT software allows the user in the Setup report to define
cycles (i.e. Qual Start to Qual End.). Cycles can also be added or modified in the Reporting
Tool prior to generation of reports.