Users Manual Part 2
Table Of Contents
- Appendix B. Regulatory Compliance and Agency Approvals
- Chapter 1. Kaye ValProbe RT System
- Chapter 2. Kaye ValProbe RT Hardware
- Chapter 3. ValProbe RT System Connections
- Chapter 4. Creating User Accounts
- Chapter 5. Defining Equipment
- Chapter 6. Defining Assets
- Chapter 7. Defining Study Setups
- Chapter 8. Viewing Live Data
- Chapter 9. Qualification Study
- Chapter 10. Sensor Verification
- Chapter 11. Qualification Reports
- Appendix A. Specifications
- A.1 Kaye ValProbe RT System
- A.1.1 List of Certified Countries
- A.1.2 Regulatory Compliance
- A.1.3 RF System Operating Frequency and Modulation
- A.1.4 RF Channels
- A.1.5 RF Network Topology and PAN ID (Network ID)
- A.1.6 Antenna Diversity
- A.1.7 Data Rate and Data Encryption
- A.1.8 RF Range (Line of Sight and Outdoor)
- A.1.9 Number of Loggers and Sensors Supported
- A.1.10 Sensor Sampling Rate
- A.1.11 Data Transmission Rate
- A.1.12 Sensor Samples Data Storage Capacity
- A.1.13 Optional Extendable Base Station Antenna
- A.2 Kaye ValProbe RT Base Station
- A.2.1 Input Power and Adaptor Ratings
- A.2.2 Installation Category
- A.2.3 Overvoltage Category and Electrical Safety Protection Class
- A.2.4 Input DC Power On/Off Switch
- A.2.5 Front Panel LED Indications and Buzzer
- A.2.6 Bath and IRTD Interface Ports
- A.2.7 USB Port
- A.2.8 Ethernet Communication Port
- A.2.9 Reset Switch to Reload Default Factory Settings
- A.2.10 Wakeup Magnet
- A.2.11 Batteries
- A.2.12 Unit Dimensions
- A.2.13 Enclosure Material
- A.2.14 Environmental Ratings
- A.3 Kaye ValProbe RT Logger
- A.3.1 Installation Category
- A.3.2 Overvoltage Category and Electrical Safety Protection Class
- A.3.3 Magnetic Switch
- A.3.4 LED Indications
- A.3.5 Calibration
- A.3.6 Real Time Clock Accuracy
- A.3.7 Sensing Elements
- A.3.8 Housing Material
- A.3.9 Logger Base Dimensions
- A.3.10 Ingress Protection
- A.3.11 Insulating Canister X2545
- A.3.12 Battery
- A.3.13 Shelf Life
- A.3.14 Battery Life
- A.4.1 Measurement Accuracy
- A.4.2 Body Environmental Ratings:
- A.4.3 Number of Input Channels
- A.4.4 Sensor Types and Measurement Range
- A.4.5 Sensor Lengths
- A.5.1 Measurement Accuracy
- A.5.2 Body Environmental ratings:
- A.5.3 Number of Input Channels
- A.5.4 Sensor Types and Measurement Range
- A.5.5 Sensor Lengths
- A.6.1 Measurement Accuracy
- A.1 Kaye ValProbe RT System
- Appendix B. Regulatory Compliance and Agency Approvals
- B.1 Electrical Safety Approvals:
- B.2 Radio and EMC Certification Approvals:
- B.3 Ingress Protection for Kaye ValProbe RT Logger
- B.4 United States FDA 21 CFR Part 11 Complaint Software Application
- B.5 Transportation Regulations
- B.6 FCC Compliance Statement
- B.7 ISED Canada Compliance Statement
- B.8 EU Compliance Statement:
- B.9
- Product Certification Labels
- Appendix C. Environnemental Compliance
- Appendix D. Warranty and Returns:
- Appendix E. Service Information
Chapter 11: Qualification Reports
Kaye ValProbe RT User Manual 106
The first vertical red line indicates the time the first Temperature sensor reached the
lethality base temperature (Tb). The lethality base temperature is marked by the
horizontal red line.
The second vertical line is either 15 or 30 seconds after the first Temperature sensor
reached the base temperature, depending on the time period you select. The text at the
top right of the graph indicates if the sensors passed (including the actual equilibration
time) or failed according to the equilibration criteria.
From Graph Report screen, check the Equilibrium box to open the Edit Sensors screen.
From this screen you can:
• Select/unselect sensors
• Select the Reference Sensor from the drop-down list
• Enter a reference temperature
• Choose a time of 15 or 30 seconds from the drop-down list
• Select OK to display the Equilibration Time graph
Important:
• Excluded sensors from any graph reports are not included in the calculation graphs.
• Groups with only one sensor have no statistical calculations available and the
checkboxes are grayed out.
• The Lethality calculation is only available if lethality has been defined for the study.
• The saturation pressure calculation is only available if the study includes at least
one temperature sensor along with a pressure sensor.
• The saturation temperature calculation is only available if the study includes at least
one pressure sensor along with temperature sensors.
• The Equilibrium calculation is only accessible if the Qualification data storage rate
is 1 sec.
The following buttons on the bottom of the screen offer additional graphing options:
Zoom
By utilizing the zoom icons at the bottom of the screen or by using your fingers
you can zoom in or out or rest the zoom for enhanced analysis.
Y / X Scaling
Pressing the Manual Y – Scale button allows you to manually adjust the Y axis scale.
The X-Axis Display button allows you to select different options for displaying the X
time axis.