User's Manual

Table Of Contents
21 of 64936.5468 0.92
5.3 Set the SNMP and FTP Parameters
1. Open the master C-hubs web GUI as described under 4.3, p. 15/4.4, p. 21.
2. Go to Settings LAN Connectivity.
3. Set Protocol Select to SNMP if the network management system (NMS) supports the
SNMP protocol (①ⓐ in Fig. 9).
4. Set the SNMP parameters .
5. Set the C-hub parameters .
5.4 Update the K-BOW System Software
If required, the K-BOW system software can be updated locally or via FTP.
For details, see the document Operation and Maintenance (K-BOW Platform 2)
5.4.1 Update via FTP
If FTP remote software upgrades shall be supported:
1. Set the FTP server parameters
1)
( in Fig. 10).
2. Select the FTP File Transfer Control checkbox ⑤ⓐ.
3. Select Start Upgrade ⑤ⓑ and press Set .
The update via FTP is performed.
1)
The FTP server parameters are located on the same tab as the SNMP/C-hub parameters.
3
2
1
a
Fig. 9: SNMP parameters (C-hub)