User Guide
Additional setup 71
Table 3. Report detail levels
Level Level name Meaning
0 Fatal Errors Only information regarding critical errors (that
terminate the program due to impossibility of
executing an action). For example, the component
is infected, or scanning, database loading, or
license key loading failed.
1 Errors Information about other errors that may or may not
lead to application shutdown, for example, file scan
errors.
2 Warning Notifications about errors that may lead to the
application shutdown (license key expiration
warning, out-of-disk-space warning, etc.).
3 Info, Notice Important informational messages, such as
whether a component is running or inactive, the
path to the configuration file, latest changes in scan
area, database updates, license keys, statistics
summary.
4 Activity Messages on scanning of files according to the
report detail level.
9 Debug All debug messages.
Information regarding fatal errors that occur during component operation is
output regardless of the preset detail level. The default level is 3.
To define the report level, set the ReportLevel parameter of the
[updater.report] section to the desired value.
The reports of any detail level are displayed as:
[date time level_of_detail] STRING
where:
[date time level_of_detail] is the parameter generated by the
system. It contains the date and time (in the format set by the
administrator) and the report detail level (the first letter of the detail
level).