120V compressors are supplied with a NEMA 5-15 Plug which can be plugged into a 120V receptacle. 240V
compressors are supplied with flying leads. The leads can be hard-wired into 240V service or a plug can be
installed on the cord if plugging into a receptacle.
Kasco Marine highly recommends that the site service providing the system have a human-rated Ground Fault
Circuit Interrupter outlet (120V) or human-rated Ground Fault breaker (240V) for your protection. Contact a
licensed electrician to bring 120 or 240 volts (depending on which model is purchased), single phase electrical
supply to the compressor location and to install appropriate human-rated ground fault protection
Base Mount Cabinet Installation
Choose a location for placing your base mount cabinet assembly. The location should be placed far enough
from shore to avoid the potential of flooding. Plantings can be used to help hide the cabinet from sight, however
be sure that both the inlet and outlet vents will not be blocked as fresh air is needed to keep the compressor
from over-heating.
The cabinet can be placed directly on the ground or can be permanently attached to a concrete pad. The bottom
feet of the cabinet have holes which can be used to anchor the cabinet in place.
The cabinet should be placed adjacent to the electrical service which will provide power to the system. The
cabinet will have 6 foot power cord(s) with plugs. DO NOT USE EXTENSION CORDS.