Product Manual
6
OWNERS MANUAL
Parts included in RA(H)4-NC, RA(H)5-NC and RA(H)6-NC Systems:
(4 - 6) Robust-Aire Diffuser Assembly
(4 - 6) 3/8” x 100’ SureSink Tubing w/fitting kit
(2) Double Head Compressor
(2) ¼” NPT x 3/8” barb brass elbow
(8) Compressor Vibration Isolation Feet
(8) ¼” Flat Washer
(8) ¼” Lock Nut
(2) Cooling fan assembly (either 115V with plug or 230V without plug
(8) #10 x 3/4” bolt
(8) #10 split washer
(8) #10 Nut
(4) Hose clamp
(2) Two or Three Station Manifold Assembly
(4) Manifold Mounting Screw
Installation Tools & Materials:
Phillips Screwdriver
5/16” socket/nut driver
1/4” socket/nut driver
9/32” socket/nut driver
3/8” driver for #10 nuts
7/16” driver for 1/4” nuts
Flat head screwdriver
PTFE thread sealant (Teflon tape)
No Cabinet System Installation Requirements
Correct installation is your responsibility. Make sure you have the proper installation conditions and that installation
clearances do not block air flow.
• Compressor needs to be installed in a clean, dry location.
• Compressor needs to be protected from dirt and moisture and from the outdoor environment such as rain,
snow, flooding.
• Ambient air temperature (temperature readings taken 4” away from any surface of the compressor) must not
exceed 104° F (40°C).
• Adequate ventilation and cooling air (air flow across the compressor) must be provided to keep the
compressor from overheating and causing premature damage. The included fan has been provided for this
purpose.
• Kasco Marine includes with no cabinet systems a simple, durable bracket accessory that will allow you to
easily mount the compressor to a wall, floor or bench.
After the proper location has been determined, use the following diagram to complete the installation.