User guide
7
Tools & Supplies Needed:
A. Anchors or stakes for installing unit (2 or 3 de-
pending on unit)
B. 208-240V Electrical Supply near pond on a post
C. Two (or 3 depending on model) 30cm pieces of 
2.54cm galvanized pipe for weighting ropes (optional)
D. 9/16”(14mm) & 7/16” (11mm) Nut Driver
E. 9/16” (14mm) & 7/16” (11mm) Socket
Adjustable crescent wrench
8400EA, 2.3EA, 3.1EA, 3.3EA 
Assembly
STEP ONE
Remove all contents from package and place on a 
clean, fl at surface. Inspect the shipment for any dam-
ages. Make sure you have all the parts needed. 
STEP TWO
Arrange the three Float Sections (Part B1) upright 
(plug on bottom) so the overlap of one section aligns 
with the next section and loosely push the three sec-
tions together to form a continuous ring.
Float up
Float down
(plug)
STEP THREE
Position one Top Float Bracket (Part B2) so that the bolt 
holes in the bracket align with the bolt holes in the two 
adjoined fl oat sections and insert two 9” Black Coated 
Bolts (Part B4) through the assembly. This may require 
some minor repositioning of the fl oat sections as you push 
the bolt all the way through. Do not force the bolt through.  
Repeat for the remaining two joints.
STEP FOUR
Turn the assembly upside down and place the Bottom Float 
Brackets (Part B3) over the bolts, the ends of which should 
STEP SIX
Turn the assembly upright again. At this time, if the 
cord contains a metal strain relief, you can use the 
chain connector and attach it in one of the opening at 
the rope placement. The chain connector will easily fi t 
if installed from the bottom or top side of the opening.  
It will not fi t if installed from side of opening. Use the 
Nylon Cable Tie (Part I) included to secure the power 
cord to a molded hole in the fl oat to prevent cord 
damage if there is no strain relief on the cord. If a 
Strain Relief is present on the cord, you may disregard 
the Nylon Tie. On cords with a Quick Disconnect, 
the disconnect should be tightened properly to avoid 
leaking. If installing a new Quick Disconnect, refer to 
Quick Disconnect Instructions. If ready to install in 
the pond, go to Installation instructions.
8400EA, 2.3EA, 3.1EA, 3.3EA Parts
B2. Large Float Ring 
See Diagram below. 
  1. Float Section (3)
  2. Top Float Bracket (3)
  3. Bottom Float Bracket w/Rope (3)
  4. 9” x 3/8” Bolt (6)
  5. 3/8” Lock Nut (6)
  6. 3/8” x 1” Bolt (3)
  7. 3/8” Lock Washer (3)
  8. Bottom Screen (1 - optional)
  9. Bottom Screen Clips (3 - optional)
Note: Extra hardware may be included.