PACKAGING:
Available in 1 gallon cans, 5 gallon pails and 55 gallon drums.
Note: Coating Modified Bitumen Membranes with Aluminum
Coatings:
Karnak recommends coating torch-applied modified bitumen membranes as soon
as possible after the membrane is installed.
Karnak’s experience, laboratory and field tests, as well as NRCA, RCMA and ARMA
reports, indicate that aluminum coating will reduce the combined effects of
ultraviolet rays, heat and moisture, which, especially on APP modified bitumens,
enhance exudation that can cause discoloring and delamination of any surface
coating
COLD-PROCESS SYSTEMS AND COATINGS, EITHER EMULSION OR SOLVENT
BASED, SHOULD ONLY BE INSTALLED ON DECKS WITH POSITIVE DRAINAGE.
PER NRCA, (NATIONAL ROOFING CONTRACTORS ASSOCIATION) “THE
CRITERIA FOR JUDGING PROPER SLOPE FOR DRAINAGE IS THAT THERE BE NO
EVIDENCE OF STANDING WATER ON THE DECK 48 HOURS AFTER IT STOPS
RAINING.”
If further information is required, please contact Karnak’s Technical
Service Department at 1-800-526-4236.