Operation Manual
14 - English
Care and Maintenance
Cleaning
Before long periods of storage, e.g. in winter:
• Pull the cleaning agent metering valve off the cle-
aning agent suction hose and clean it under run-
ning water.
• Pull out the strainer in the water inlet with flat-nose
pliers and clean it under running water.
Maintenance
The unit is maintenance-free.
Help with faults
Faults often have simple causes which you can rec-
tify yourself with the aid of the following summary. In
case of doubt or of faults or remedies not mentioned
here apply to the authorized customer service.
!
Danger of electric shock!
Repair work on the unit can only be carried out by the
authorized customer service.
Appliance does not Work
-Check whether the voltage shown on the rating plate
corresponds to that of the power source.
-Check the connector cable for damage.
Appliance does not reach Operational Pressure
-Vent the appliance:Allow the pump to operate wit-
hout the high-pressure hose until water appears at
the high-pressure outlet without any more
bubbles.Then reattach the high-pressure hose.
-Clean the strainer in the water connection.
-Check the inlet water flow rate.
-Check all inlet pipes to the pump for leaks or block-
age.
Strong Pressure Fluctuations
-Clean the high-pressure nozzle. Remove dirt from
the nozzle hole with a needle and then rinse out with
water from the front.
Pump Leaks
-10 drops per minute are permissible. In the case of
more serious leakage, you should contact the autho-
rized customer service.
No Detergent Suction
-Clean the detergent suction hose with filter, and check
for leaks.
Replacement parts
Use exclusively original replacement parts. You will
find a replacement parts summary at the end of these
operating instructions.
Guarantee
In the case of a claim under the guarantee please
contact your dealer or the nearest authorized custo-
mer service point, accompanying your claim with
accessories and purchase voucher.
Technical Data
Power supply
Voltage (at 1~50 Hz) 230-240 V
Connected load 1.2 kW
Supply fuses (time-lag) 10 A
Safety class 1
Water connection
Supply temperature (max.) 40 °C
Supply volume (min.) 600 l/h
Supply pressure (max.) 2-12 bar
Performance data
Operating pressure 85 bar
max. permissible pump pressure 100 bar
Flow volume 300 l/h
Cleaning agent metering 20 l/h
Suction height from
open container (20 °C) 1 m
Recoil force of the handgun 10 N
Unit vibrations 0,8 m/s²
Sound level L
PA
(EN60704-1) 74 dB(A)
Dimensions
Length/Width/Height 375/204/294 mm
Weight 10 kg
Circuit Diagram
C1 Capacitor
M1 Motor
Q1 Switch
T Temperature limiter
S1 Pressure switch