Safety data sheet

Multi-purpose floor cleaning RM 536
Safety Data Sheet
according to the Hazardous Products Regulation (February 11, 2015)
03/12/2020
CA - en
Decomposition temperature
:
No data available
Flammability (solid, gas)
:
Not applicable
Vapour pressure
:
No data available
Vapour pressure at 50 °C
:
No data available
Relative density
:
No data available
Density
:
1 g/cm³ (20 °C)
Solubility
:
Water: completely miscible
Partition coefficient n-octanol/water (Log Pow)
:
No data available
Viscosity, kinematic
:
No data available
Viscosity, dynamic
:
3 mPa·s
Explosive properties
:
Product is not explosive.
Oxidising properties
:
Non oxidizing.
Explosive limits
:
No data available
9.2. Other information
Refractive index
:
1.3389
SECTION 10: Stability and reactivity
10.1. Reactivity
Reactivity
:
The product is non-reactive under normal conditions of use, storage and transport.
Chemical stability
:
Stable under normal conditions.
Possibility of hazardous reactions
:
No dangerous reactions known under normal conditions of use.
Conditions to avoid
:
None under recommended storage and handling conditions (see section 7).
Hazardous decomposition products
:
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
SECTION 11: Toxicological information
11.1. Information on toxicological effects
Acute toxicity (oral)
:
Not classified (Based on available data, the classification criteria are not met)
Acute toxicity (dermal)
:
Not classified (Based on available data, the classification criteria are not met)
Acute toxicity (inhalation)
:
Not classified (Based on available data, the classification criteria are not met)
Ethanol (64-17-5)
LD50 oral rat
10470 mg/kg (OECD 401 method)
LC50 inhalation rat (Vapours - mg/l/4h)
124.7 mg/l/4h (OECD 403)
Skin corrosion/irritation
:
Not classified (Based on available data, the classification criteria are not met)
pH: 9
Serious eye damage/irritation
:
Not classified (Based on available data, the classification criteria are not met)
pH: 9
Respiratory or skin sensitization
:
Not classified (Based on available data, the classification criteria are not met)
Germ cell mutagenicity
:
Not classified (Based on available data, the classification criteria are not met)
Carcinogenicity
:
Not classified (Based on available data, the classification criteria are not met)
Reproductive toxicity
:
Not classified (Based on available data, the classification criteria are not met)
STOT-single exposure
:
Not classified (Based on available data, the classification criteria are not met)
STOT-repeated exposure
:
Not classified (Based on available data, the classification criteria are not met)
Aspiration hazard
:
Not classified (Based on available data, the classification criteria are not met)
Multi-purpose floor cleaning RM 536
Viscosity, kinematic (calculated value) (40 °C)
3 mm²/s
SECTION 12: Ecological information
12.1. Toxicity
Hazardous to the aquatic environment, short-term
(acute)
:
Not classified (Based on available data, the classification criteria are not met)