SECTION 3: Composition/Information on ingredients
3.1. Substances
Not applicable
3.2. Mixtures
Name
Product identifier
%
GHS-US classification
ethanol
(CAS-No.) 64-17-5
2.5 - 5
Flam. Liq. 2, H225
Eye Irrit. 2A, H319
Poly(oxy-1,2-ethandiyl).alpha.-tridecyl-.omega.-hydoxy-,branched
(CAS-No.) 69011-36-5
1 - 2.5
Acute Tox. 4 (Oral), H302
Eye Dam. 1, H318
Full text of hazard classes and H-statements : see section 16
SECTION 4: First-aid measures
4.1. Description of first aid measures
First-aid measures general
:
When in doubt or if symptoms are observed, get medical advice.
First-aid measures after inhalation
:
Remove person to fresh air and keep comfortable for breathing.
First-aid measures after skin contact
:
Wash skin with plenty of water.
First-aid measures after eye contact
:
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.
Continue rinsing. If eye irritation persists: Get medical advice/attention.
First-aid measures after ingestion
:
Call a poison center/doctor/physician if you feel unwell.
4.2. Most important symptoms and effects (acute and delayed)
Symptoms/effects after eye contact
:
Eye irritation.
4.3. Immediate medical attention and special treatment, if necessary
Treat symptomatically.
SECTION 5: Fire-fighting measures
5.1. Suitable (and unsuitable) extinguishing media
Suitable extinguishing media
:
Water spray. Dry powder. Foam. Carbon dioxide.
Unsuitable extinguishing media
:
Strong water jet.
5.2. Specific hazards arising from the chemical
Reactivity
:
The product is non-reactive under normal conditions of use, storage and transport.
5.3. Special protective equipment and precautions for fire-fighters
Protection during firefighting
:
Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus.
Complete protective clothing.
Other information
:
Do not allow run-off from fire fighting to enter drains or water courses. Disposal must be done according
to official regulations.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
Protective equipment
:
No specific measures are necessary.
Emergency procedures
:
Ventilate spillage area. Avoid contact with skin and eyes.
6.1.2. For emergency responders
Protective equipment
:
Do not attempt to take action without suitable protective equipment. For further information refer to
section 8: "Exposure controls/personal protection".
6.2. Environmental precautions
Avoid sub-soil penetration. Prevent entry to sewers and public waters.