Safety data sheet
Page 5/13
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 30.04.2021 Revision: 27.04.2021Version number 5
Trade name:
FloorPro Intensive Deep Cleaner Extra RM 752
(Contd. of page 4)
52.0.1.1
SECTION 8: Exposure controls/personal protection
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
The product does not contain any relevant quantities of materials with critical values that have to be monitored
at the workplace.
·
DNELs
1310-73-2 sodium hydroxide
Inhalative DNEL 1 mg/m3 (employee)
1 mg/m3 (consumer)
15763-76-5 sodium p-cumenesulphonate
Oral DNEL 3.8 mg/kg*d (consumer)
Dermal DNEL 136.25 mg/kg*d (employee)
68.1 mg/kg*d (consumer)
Inhalative DNEL 26.9 mg/m3 (employee)
6.6 mg/m3 (consumer)
·
PNECs
15763-76-5 sodium p-cumenesulphonate
PNEC 0.23 mg/l (freshwater)
0.023 mg/l (marine water)
100 mg/l (STP)
PNEC sediment 0.862 mg/kg (freshwater)
0.086 mg/kg (marine water)
PNEC soil 0.037 mg/kg (soil)
·
8.2 Exposure controls
·
Appropriate engineering controls
No further data; see item 7.
·
Individual protection measures, such as personal protective equipment
·
General protective and hygienic measures
Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
Avoid contact with the eyes and skin.
·
Respiratory protection:
Filter A/P2.
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure
use self-contained respiratory protective device.
Not necessary if room is well-ventilated.
·
Hand protection
Protective gloves.
(Contd. on page 6)
EU