Safety data sheet

Page 4/10
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 03.12.2021 Revision: 13.11.2019Version number 4 (replaces version 1)
Trade name:
SurfacePro Surface Cleaner CA 30 C eco!perform
(Contd. of page 3)
53.2.5
SECTION 8: Exposure controls/personal protection
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
The product does not contain any relevant quantities of materials with critical values that have to be monitored
at the workplace.
·
DNELs
67-63-0 propan-2-ol
Oral DNEL 26 mg/kg*d (consumer)
Dermal DNEL 888 mg/kg*d (employee)
319 mg/kg*d (consumer)
Inhalative DNEL 500 mg/m3 (employee)
89 mg/m3 (consumer)
·
PNECs
67-63-0 propan-2-ol
PNEC 140.9 mg/l (freshwater)
140.9 mg/l (marine water)
140.9 mg/l (STP)
2,251 mg/l (STP)
PNEC sediment 552 mg/kg (freshwater)
552 mg/kg (marine water)
PNEC soil 28 mg/kg (soil)
·
8.2 Exposure controls
·
Appropriate engineering controls
No further data; see item 7.
·
Individual protection measures, such as personal protective equipment
·
General protective and hygienic measures
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
·
Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure
use self-contained respiratory protective device.
Not necessary if room is well-ventilated.
·
Hand protection
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/
the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
·
Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality
and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the
resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the
application.
(Contd. on page 5)
EU