- 8
No dry ice pel-
lets in the com-
pressed air jet
Dry ice dosing switched off (IB 7/40 Advanced on-
ly), button "Dry ice dosing on/off" on the jet gun
lights glows red, display shows "Ice off".
Press the dry ice dosing key on the jet pistol. Operator
Dry ice container is empty Refill the dry ice container Operator
Dry ice has melted Empty the dry ice container and refill it with fresh
dry ice pellets.
Operator
Vibrator on the dry ice container is not working Call Customer Service. Operator
Drive motor of the dosing equipment is overload-
ed
Let the dosing thaw Operator
Compressed air is exiting into the dry ice contain-
er
Clean the pressure balance channel in the dosing
equipment.
Customer
Service
Dosing disc in the dosing unit is defective Replace the dosing disc. Customer
Service
Fault Possible cause Remedy By whom
Technical specifications
Electrical connection
Voltage V 100...110
Current type 1~
Frequency Hz 50
Connected load kW 0,6
FI safety switch delta I in A 0,03
Compressed air
Nominal width of hose Inch 1/2
Pressure supply (max.) MPa (bar) 1,0 (10)
Pressure supply (min.) MPa (bar) 0,2 (2)
Compressed air consumption m
3
/min 0,5...3,5
Quality of compressed air min. Class 3, ISO 8573-1
Performance data
Jet pressure (max.) MPa (bar) 1,0 (10)
Diameter of dry ice pellets (max.) mm 3
Dry ice consumption kg/h 15...50
Dimensions
Contents of dry ice container kg 18
Width mm 510
Depth mm 768
Height mm 1096
Weight of IB 7/40 Classic, ready to operate kg 96
Weight of IB 7/40 Advanced, ready to operate kg 98
Weight of IB 7/40 Classic, empty, without acessories kg 70
Weight of IB 7/40 Advanced, empty, without acessories kg 71
Weight of the jet equipment (spray agent hose, spray gun, tool case) kg 6,75
Recoil force of hand spray gun (max.) N 30
Torque of jet pistol (max.), only with angled nozzle N 8
Machine vibrations
Jet pistol m/s² 1,2
Hose for spraying agent m/s² 1,2
19EN