SC 2 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them.
Contents Scope of delivery General information . . . . . . . . . . . . .2 Safety Instructions for Steam Cleaners . . . . . . . . . . . . . . . . . . . . . . . . . .3 Description of the Appliance. . . . . . .7 Quick Reference . . . . . . . . . . . . . . .8 Operation . . . . . . . . . . . . . . . . . . . . .9 How to Use the Accessories . . . . . 11 Care and maintenance. . . . . . . . . .13 Troubleshooting . . . . . . . . . . . . . . .14 Customer service . . . . . . . . . . . . . .
Safety Instructions for Steam Cleaners – – Apart from the notes contained herein the general safety provisions and rules for the prevention of accidents of the legislator must be observed. Warnings and notes that are attached on the appliance provide important notes for the safe operation. Hazard levels DANGER Pointer to immediate danger, which leads to severe injuries or death. 몇 WARNING Pointer to a possibly dangerous situation, which can lead to severe injuries or death.
Safe handling DANGER The user must use the appliance as intended. The person must consider the local conditions and must pay attention to other persons in the vicinity when working with the appliance. The appliance may not be operated in explosive atmospheres. If the appliance is used in hazardous areas the corresponding safety provisions must be observed. Do not use the appliance if it fell down, is visibly damaged or leaking.
Descaling the boiler 몇 CAUTION Do not screw the safety lock onto the appliance during decalcification. Do not use the steam cleaner as long as there is decalcifying agent in the boiler. Be careful when filling and draining the steam cleaner with the decalcifying solution. The decalcifying solution can corrode sensitive surfaces. Symbols on the machine 몇 CAUTION Symbols depending on unit type.
Description of the Appliance A1 Indicator lamp (green) – line voltage is on A2 Indicator lamp - heater (ORANGE) A3 Safety cap/lock A4 Holder for accessories A5 Storage holder for floor nozzle A6 Mains cable with mains plug A7 Running wheels (2 ea.
Quick Reference 1 2 3 Unscrew the safety lock and fill the steam cleaner with a max. of 1 litre of water. Screw in safety cap. Plug in the mains plug. The green and orange indicator lamps light up. 4 5 Wait until the orange indicator lamp goes out. Connect the accessories to the steam gun. The steam cleaner is ready to use.
Operation G 4.
Attaching the Accessories Turning on the Appliance Illustration Insert steering roller and transport wheels and lock them. Illustration Connect the required accessories (see Chapter "How to use the accessories“) to the steam gun. Insert the open end of the accessory on the steam gun and push onto the steam gun until the unlocking button of the steam gun locks into place. Illustration Use the extension tubes if necessary. To do so, connect one or both extension tubes to the steam gun.
Refilling Water Water needs to be filled into the boiler, if the steam volume decreases during work and no more steam is emitted in the end. Note: The safety lock cannot be opened as long as slight pressure remains in the boiler. Disconnect the mains plug from the socket. Push the steam switch until steam discharge stops. Now, the boiler of the appliance is unpressurized. Remove the safety lock from the device. Fill the boiler with a maximum of 1 liters of fresh tap water.
Steam gun Floor nozzle You can use the steam gun without any additional accessories, e.g.: – to remove odours and wrinkles from hanging clothes by steaming them at a distance of 10 to 20 cm. – to remove dust from plants. Here, keep a distance of 20-40 cm. – for moist dusting, by briefly steaming the cloth and wiping the furniture with it. Suited for all washable walls and floor coverings, e.g. stone floors, tiles and PVC floors.
Care and maintenance Rinsing the boiler Rinse the steam cleaner boiler at the latest after 10 boiler fillings. Fill the boiler with water and shake it strongly. This dissolves lime scaling residing on the boiler bottom. Empty water out. Descaling the boiler Note: If you always use usual commercial distilled water it is not necessary to descale the boiler.
Troubleshooting Customer service Often, failures have simple causes and you can do the troubleshooting yourself using the following overview. If you are in doubt or if the failure is not listed here please contact the authorized customer service. Australia KÄRCHER Pty. Ltd. 40 Koornang Road Scoresby, Victoria 3179 Long heating-up time 1800 675 714 (Free Call) www.karcher.com.au Steam boiler is decalcified Descale the steam boiler. No steam No water in the steam boiler. Turn off the appliance.
Technical specifications Power connection Voltage Protective class Protection class Performance data Heating output Operating pressure max. Heating time Steam volume Continuous steaming Steam push max.
English