Use and Care Manual

– 5
Technical specifications
NT 25/1 Ap NT 35/1 Ap
Mains voltage V 120 120
Frequency Hz 1~ 60 1~ 60
Rated current A 9 9
Container capacity gal (l) 6.6 (25) 9.2 (35)
Filling quantity (liquid) gal (l) 3.4 (13) 6.9 (26)
Air volume (max.) CFM (l/s) 123 (58) 123 (58)
Negative pressure (max.) mm (kPa) 2250 (22.0) 2250 (22.0)
Type of protection -- IPX4 IPX4
Protective class II II
Suction hose connection (C-DN/C-
ID)
in (mm) 1.38 (35) 1.38 (35)
Length x width x height in (mm) 20.0 x 14.5 x 19.0
(510 x 370 x 480)
20.0 x 14.5 x 22.5
(510 x 370 x 575)
Typical operating weight lbs (kg) 24.3 (11.0) 25.4 (11.5)
Max. ambient temperature °F (°C) 104 (+40) 104 (+40)
Values determined to EN 60335-2-69
Sound pressure level L
pA
dB(A) 70 70
Uncertainty K
pA
dB(A) 1 1
Power cord SJTW-A 2/16 AWG
Part no.: Cable length
CUL 6.648-370.0 25 ft (7.5 m)
12 EN