Operating instructions
Table Of Contents
- Contents
- About this operating instructions manual
- Environmental protection
- Safety instructions
- Operation
- Open the system
- Settings
- Main switch
- Adjust compressor
- Setting dosing pumps
- Dry foam station
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Blending device (option)
- Controls
- SB MB standard
- SB MB comfort
- Normal operation
- Open the menu "customer settings"
- Select the parameter you want to set
- Set the parameter with a variable
- Setting a parameter with several variables
- Exiting the menu
- Operating times
- Lighting time
- Fixed holidays
- Non-fixed holidays
- Date / Time
- Coin value
- Programme run times
- System settings
- Setting the dosing pumps
- System
- Hot blowers
- Washing station heater
- Frost protection with lost water
- Emergency frost protection
- External thermostat
- Filling in detergents
- Manual interventions
- Sales indicator
- Frost protection
- Shutting down
- Shutdown
- Function
- Flowchart system with wet foam
- Flowchart system with dry foam
- Attachment kit disconnection from mains (optional)
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Frost protection 1-tool (option, SB- MB 2 pump Fp only)
- Frost protection 2-tool, wet foam (option, SB-MB 2 pump Fp only)
- 4. Type of water
- Internal frost protection (optional)
- External frost protection (optional)
- Washing place heating (option)
- Monitoring and safety devices
- Overflow valve of high-pressure pump
- Safety valve
- Thermostat mixing valve
- Flame monitoring
- Exhaust thermostat
- Temperature controller
- Temperature controller
- Flow monitor
- Water shortage safeguard
- Motor protection switch
- Hard water sensor
- Pressure switch for RO water shortage
- Level switch Buffer tank is full
- Level sensor pump RO on
- Level switch Buffer tank is empty
- Temperature limiter 4. type of water / warm (option)
- Technical specifications
- Maintenance and care
- Troubleshooting
- Who may remedy faults?
- Fault indication
- Faults shown in the display
- Acknowledge the faults
- Viewing the list of faults
- Viewing the event list
- Interruptions in warm water circulation
- Malfunctions of the washing station heater
- Burner malfunctions with oil-heated devices
- Burner malfunctions with gas-heated devices
- Malfunctions at coin mechanism
- Faults on high pressure pumps
- Disturbed detergent supply
- Malfunctions on the wheel cleaner/intensive foam
- Faults in the compressor
- Faults at the dry foam production (option)
- Interruptions in water preparation
- Faults on the frost protection units)
- Accessories
- Warranty
- Transport
- Storage
- Installing the unit (only for experts)
- Preparing the installation place
- Unpack the equipment
- Aligning the unit and installing it
- Assemble the installation parts
- Water connection
- Electrical connection
- Fuel pipe to the external fuel tank
- Connect the washing station heater and start it up
- Check oil level
- Filling in detergents
- Initial startup
- Turning the base exchanger on
- Start-up of the RO plant
- Check the pressure of rim cleaner (option)
- Check the function of the system
- Starting up the gas burner (option)
- Dimension drawing for CAB model
- Dimension drawing for SKID model
- Dimension drawing for SKID model with WSO upgrade kit
- EU Declaration of Conformity
- Log of high pressure testing
- 43
Permeate output is
too low; buffer tank
of permeate is often
empty
Water inlet temperature is too low Measure the temperature of the softened water and
compare it with the technical data.
Operator
Operating pressure is too low Reset the operating pressure. Customer Ser-
vice
There are calcium or mineral deposits on the fil-
ter surface of the RO membrane.
Decalcify the membrane; replace it, if necessary Customer Ser-
vice
Level switch Buffer tank is "full" is defective Check level switch. Customer Ser-
vice
There are bacteria or algae deposits on the filter
surface of the RO membrane.
Rinse the membrane thoroughly for a long time; re-
place it if necessary. In future remember: Water is of
potable quality; avoid long idling periods.
Customer Ser-
vice
There are stains on
the car paint during
Top Care (perme-
ate has not been
adequately demin-
eralised)
The mineral content of the softened water is too
high
Check conductivity of softened water. Customer Ser-
vice
RO membrane has ruptured; defective sealing Replace washer or membrane. Check conductivityCustomer Ser-
vice
Mixing of permeate and softened water Comparison of conductivity of the permeate from
the spray pipe and water from the buffer tank of per-
meate.
Customer Ser-
vice
Fault Possible cause Remedy By whom
Faults on the frost protection units)
Fault Possible cause Remedy By whom
Convector is not
running
Convector set incorrectly Check adjustment (see Chapter "Settings") Operator
Convector defective Replace the convector. Customer Ser-
vice
Frost protection is
not working
Power supply has been interrupted Check power supply and ensure proper supply. Operator
Exterior temperature sensor installed incorrect-
ly.
See section "Installing system". Customer Ser-
vice
Spray pipe, hand-
spray gun and high-
pressure hose are
frozen
Sieve with throttle plugged (marked red) Open the screw connection. Clean sieve. Check to
see whether the throttle boring moves freely.
Operator
Filter of the anti frost pump plugged Clean the filter and replace Operator
Wash station heat-
er will not work dur-
ing frost
Exterior temperature sensor installed incorrect-
ly.
See section "Installing system". Customer Ser-
vice
Heat exchanger or circulation pump is defectiveCheck heat exchanger, pump and pipe system; re-
pair, if required.
Customer Ser-
vice
Burner fault Fix burner fault. Operator
Motor protection switch for circulation pump of
washing station heater has triggered
Unlock the motor protection switch; find out the
cause if fault occurs.
Operator, Cus-
tomer Service