Operating instructions
Table Of Contents
- Contents
- About this operating instructions manual
- Environmental protection
- Safety instructions
- Operation
- Open the system
- Settings
- Main switch
- Adjust compressor
- Setting dosing pumps
- Dry foam station
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Blending device (option)
- Controls
- SB MB standard
- SB MB comfort
- Normal operation
- Open the menu "customer settings"
- Select the parameter you want to set
- Set the parameter with a variable
- Setting a parameter with several variables
- Exiting the menu
- Operating times
- Lighting time
- Fixed holidays
- Non-fixed holidays
- Date / Time
- Coin value
- Programme run times
- System settings
- Setting the dosing pumps
- System
- Hot blowers
- Washing station heater
- Frost protection with lost water
- Emergency frost protection
- External thermostat
- Filling in detergents
- Manual interventions
- Sales indicator
- Frost protection
- Shutting down
- Shutdown
- Function
- Flowchart system with wet foam
- Flowchart system with dry foam
- Attachment kit disconnection from mains (optional)
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Frost protection 1-tool (option, SB- MB 2 pump Fp only)
- Frost protection 2-tool, wet foam (option, SB-MB 2 pump Fp only)
- 4. Type of water
- Internal frost protection (optional)
- External frost protection (optional)
- Washing place heating (option)
- Monitoring and safety devices
- Overflow valve of high-pressure pump
- Safety valve
- Thermostat mixing valve
- Flame monitoring
- Exhaust thermostat
- Temperature controller
- Temperature controller
- Flow monitor
- Water shortage safeguard
- Motor protection switch
- Hard water sensor
- Pressure switch for RO water shortage
- Level switch Buffer tank is full
- Level sensor pump RO on
- Level switch Buffer tank is empty
- Temperature limiter 4. type of water / warm (option)
- Technical specifications
- Maintenance and care
- Troubleshooting
- Who may remedy faults?
- Fault indication
- Faults shown in the display
- Acknowledge the faults
- Viewing the list of faults
- Viewing the event list
- Interruptions in warm water circulation
- Malfunctions of the washing station heater
- Burner malfunctions with oil-heated devices
- Burner malfunctions with gas-heated devices
- Malfunctions at coin mechanism
- Faults on high pressure pumps
- Disturbed detergent supply
- Malfunctions on the wheel cleaner/intensive foam
- Faults in the compressor
- Faults at the dry foam production (option)
- Interruptions in water preparation
- Faults on the frost protection units)
- Accessories
- Warranty
- Transport
- Storage
- Installing the unit (only for experts)
- Preparing the installation place
- Unpack the equipment
- Aligning the unit and installing it
- Assemble the installation parts
- Water connection
- Electrical connection
- Fuel pipe to the external fuel tank
- Connect the washing station heater and start it up
- Check oil level
- Filling in detergents
- Initial startup
- Turning the base exchanger on
- Start-up of the RO plant
- Check the pressure of rim cleaner (option)
- Check the function of the system
- Starting up the gas burner (option)
- Dimension drawing for CAB model
- Dimension drawing for SKID model
- Dimension drawing for SKID model with WSO upgrade kit
- EU Declaration of Conformity
- Log of high pressure testing
- 39
1 Unlocking key for exhaust gas thermo-
stat
2 Unlock button of oil firing unit
3 Electrical box of burner control
Malfunctions on the gas burner must only be rectified by authorised expert staff of the burner manufacturer.
Burner malfunctions with oil-heated devices
Fault Possible cause Remedy By whom
Fault in oil firing (oil
firing unit) has trig-
gered in the electri-
cal box of the burn-
er control)
No ignition sparks exist (can be detected through
the looking glass in the burner lid).
Check electrode setting, ignition transformer and
ignition cable. Clean the electrodes, replace de-
fective parts.
Press the unlock button des oil firing unit.
Customer Ser-
vice
Looking glass for flame monitoring is contaminat-
ed
Clean the sight glass of the flame monitor (see
section „Maintenance work“).
Press the unlock button of the exhaust thermo-
stat.
Operator
Light sensor of flame monitor not in holder or is
defective
Refasten or replace the light sensor.
Press the unlock button of the exhaust thermo-
stat.
Operator, Cus-
tomer Service
Heating oil level is too low Filling the fuel tank.
Press the unlock button of the exhaust thermo-
stat.
Operator
No flame is formed due to lack of fuel Clean the fuel filters on the fuel pump.
Press the unlock button of the exhaust thermo-
stat.
Operator
Clean the fuel nozzle, replace if necessary.
Press the unlock button of the exhaust thermo-
stat.
Operator
Press the unlock button of the exhaust thermo-
stat.
Fuel solenoid valve, fuel pump or coupling is de-
fective.
Customer Ser-
vice
No flame is formed due to lack of air Check blower sleeve for damage and ensure that
the belts are sitting correctly.
Press the unlock button of the exhaust thermo-
stat.
Operator
Blower is defective; replace.
Press the unlock button of the exhaust thermo-
stat.
Customer Ser-
vice
Heavy smoke for-
mation during start
and during opera-
tions
Ignition electrode is lying in the fuel stream. Check electrode setting and correct it. Operator, Cus-
tomer Service
Fuel pressure setting was changed (see "Techni-
cal Specifications")
Check fuel pressure, reset, if necessary Customer Ser-
vice
Heavy soot formation on the heating coil. Dismantle boiler and clean heating coil. Customer Ser-
vice
Exhaust thermo-
stat (S5) has trig-
gered.
Warm water circulation has calcium deposits Check water preparation, decalcify circuit.
Unlock the exhaust thermostat by pressing the
key.
Customer Ser-
vice
Heavy soot formation on the heating coil. Dismantle boiler and clean heating coil.
Unlock the exhaust thermostat by pressing the
key.
Customer Ser-
vice
Burner settings wrong Correct the burner settings.
Unlock the exhaust thermostat by pressing the
key.
Customer Ser-
vice
Burner malfunctions with gas-heated devices
41EN