Operating instructions
Table Of Contents
- Contents
- About this operating instructions manual
- Environmental protection
- Safety instructions
- Operation
- Open the system
- Settings
- Main switch
- Adjust compressor
- Setting dosing pumps
- Dry foam station
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Blending device (option)
- Controls
- SB MB standard
- SB MB comfort
- Normal operation
- Open the menu "customer settings"
- Select the parameter you want to set
- Set the parameter with a variable
- Setting a parameter with several variables
- Exiting the menu
- Operating times
- Lighting time
- Fixed holidays
- Non-fixed holidays
- Date / Time
- Coin value
- Programme run times
- System settings
- Setting the dosing pumps
- System
- Hot blowers
- Washing station heater
- Frost protection with lost water
- Emergency frost protection
- External thermostat
- Filling in detergents
- Manual interventions
- Sales indicator
- Frost protection
- Shutting down
- Shutdown
- Function
- Flowchart system with wet foam
- Flowchart system with dry foam
- Attachment kit disconnection from mains (optional)
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Frost protection 1-tool (option, SB- MB 2 pump Fp only)
- Frost protection 2-tool, wet foam (option, SB-MB 2 pump Fp only)
- 4. Type of water
- Internal frost protection (optional)
- External frost protection (optional)
- Washing place heating (option)
- Monitoring and safety devices
- Overflow valve of high-pressure pump
- Safety valve
- Thermostat mixing valve
- Flame monitoring
- Exhaust thermostat
- Temperature controller
- Temperature controller
- Flow monitor
- Water shortage safeguard
- Motor protection switch
- Hard water sensor
- Pressure switch for RO water shortage
- Level switch Buffer tank is full
- Level sensor pump RO on
- Level switch Buffer tank is empty
- Temperature limiter 4. type of water / warm (option)
- Technical specifications
- Maintenance and care
- Troubleshooting
- Who may remedy faults?
- Fault indication
- Faults shown in the display
- Acknowledge the faults
- Viewing the list of faults
- Viewing the event list
- Interruptions in warm water circulation
- Malfunctions of the washing station heater
- Burner malfunctions with oil-heated devices
- Burner malfunctions with gas-heated devices
- Malfunctions at coin mechanism
- Faults on high pressure pumps
- Disturbed detergent supply
- Malfunctions on the wheel cleaner/intensive foam
- Faults in the compressor
- Faults at the dry foam production (option)
- Interruptions in water preparation
- Faults on the frost protection units)
- Accessories
- Warranty
- Transport
- Storage
- Installing the unit (only for experts)
- Preparing the installation place
- Unpack the equipment
- Aligning the unit and installing it
- Assemble the installation parts
- Water connection
- Electrical connection
- Fuel pipe to the external fuel tank
- Connect the washing station heater and start it up
- Check oil level
- Filling in detergents
- Initial startup
- Turning the base exchanger on
- Start-up of the RO plant
- Check the pressure of rim cleaner (option)
- Check the function of the system
- Starting up the gas burner (option)
- Dimension drawing for CAB model
- Dimension drawing for SKID model
- Dimension drawing for SKID model with WSO upgrade kit
- EU Declaration of Conformity
- Log of high pressure testing
- 35
Faults shown in the display
Display Cause Remedy
F 001 Electronic outlets overloaded Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 004 Dimming sensor defective Call customer service.
F 005 Protective motor switch on high pressure pumps was triggered Reset motor protection switch; call Customer Ser-
vice if the problem recurs.
F 006 Connection to RDS defective Call customer service.
F 007 The pressure switch for air on the compressor does not report any
pressure
Check the compressor and the compressed air
lines.
F 008 Cause: no connection to the electronics "MSWS". Check the plug connection of the data cable with
electronics A1
F 010 No connection to pump electronics at washing station 1 Call customer service.
F 011 Electronic outlets at washing station 1 overloaded Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 012 Current pickup of high pressure pump at washing station 1 too high
F 013 Current pickup of high pressure pump at washing station 1 too low See "Faults on high pressure pumps"
F 014 Contact of high pressure pump at washing station 1 stuck Call customer service.
F 016 Coiling protection contact of high pressure pump washing station 1 has
triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 017 Oil level of high pressure pump at washing station 1 too low Refill oil, acknowledge the fault.
F 018 Electronics at washing station 1 defective Call customer service.
F 020 No connection to remote control electronics at washing station 1 Check the connector of the data cable with the elec-
tronics of the remote control.
F 021 Fault at coin acceptor at washing station 1 Call customer service.
F 022 Check the microswitch on the mechanical coin ac-
ceptor, replace electronic coin acceptor
F 030 No connection to pump electronics at washing station 2 Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 031 Electronic outlets at washing station 2 overloaded
F 032 Current pickup of high pressure pump at washing station 2 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 033 Current pickup of high pressure pump at washing station 2 too low See "Faults on high pressure pumps"
F 034 Contact of high pressure pump at washing station 2 stuck Call customer service.
F 036 Coiling protection contact of high pressure pump washing station 2 has
triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 037 Oil level of high pressure pump at washing station 2 too low Refill oil, acknowledge the fault.
F 038 Electronics at washing station 2 defective Call customer service.
F 040 No connection to remote control electronics at washing station 2 Check the connector of the data cable with the elec-
tronics of the remote control.
F 041 Fault at coin acceptor at washing station 2 Call customer service.
F 042 Check the microswitch on the mechanical coin ac-
ceptor, replace electronic coin acceptor
F 050 No connection to pump electronics at washing station 3 Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 051 Electronic outlets at washing station 3 overloaded
F 052 Current pickup of high pressure pump at washing station 3 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 053 Current pickup of high pressure pump at washing station 3 too low See "Faults on high pressure pumps"
F 054 Contact of high pressure pump at washing station 3 stuck Call customer service.
F 056 Coiling protection contact of high pressure pump washing station 3 has
triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 057 Oil level of high pressure pump at washing station 3 too low Refill oil, acknowledge the fault.
F 058 Electronics at washing station 3 defective Call customer service.
F 060 No connection to remote control electronics at washing station 3 Check the connector of the data cable with the elec-
tronics of the remote control.
F 061 Fault at coin acceptor at washing station 3 Call customer service.
F 062 Check the microswitch on the mechanical coin ac-
ceptor, replace electronic coin acceptor
F 070 No connection to pump electronics at washing station 4 Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 071 Electronic outlets at washing station 4 overloaded
F 072 Current pickup of high pressure pump at washing station 4 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 073 Current pickup of high pressure pump at washing station 4 too low See "Faults on high pressure pumps"
37EN