Operating instructions
Table Of Contents
- Contents
- About this operating instructions manual
- Environmental protection
- Safety instructions
- Operation
- Open the system
- Settings
- Main switch
- Adjust compressor
- Setting dosing pumps
- Dry foam station
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Blending device (option)
- Controls
- SB MB standard
- SB MB comfort
- Normal operation
- Open the menu "customer settings"
- Select the parameter you want to set
- Set the parameter with a variable
- Setting a parameter with several variables
- Exiting the menu
- Operating times
- Lighting time
- Fixed holidays
- Non-fixed holidays
- Date / Time
- Coin value
- Programme run times
- System settings
- Setting the dosing pumps
- System
- Hot blowers
- Washing station heater
- Frost protection with lost water
- Emergency frost protection
- External thermostat
- Filling in detergents
- Manual interventions
- Sales indicator
- Frost protection
- Shutting down
- Shutdown
- Function
- Flowchart system with wet foam
- Flowchart system with dry foam
- Attachment kit disconnection from mains (optional)
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Frost protection 1-tool (option, SB- MB 2 pump Fp only)
- Frost protection 2-tool, wet foam (option, SB-MB 2 pump Fp only)
- 4. Type of water
- Internal frost protection (optional)
- External frost protection (optional)
- Washing place heating (option)
- Monitoring and safety devices
- Overflow valve of high-pressure pump
- Safety valve
- Thermostat mixing valve
- Flame monitoring
- Exhaust thermostat
- Temperature controller
- Temperature controller
- Flow monitor
- Water shortage safeguard
- Motor protection switch
- Hard water sensor
- Pressure switch for RO water shortage
- Level switch Buffer tank is full
- Level sensor pump RO on
- Level switch Buffer tank is empty
- Temperature limiter 4. type of water / warm (option)
- Technical specifications
- Maintenance and care
- Troubleshooting
- Who may remedy faults?
- Fault indication
- Faults shown in the display
- Acknowledge the faults
- Viewing the list of faults
- Viewing the event list
- Interruptions in warm water circulation
- Malfunctions of the washing station heater
- Burner malfunctions with oil-heated devices
- Burner malfunctions with gas-heated devices
- Malfunctions at coin mechanism
- Faults on high pressure pumps
- Disturbed detergent supply
- Malfunctions on the wheel cleaner/intensive foam
- Faults in the compressor
- Faults at the dry foam production (option)
- Interruptions in water preparation
- Faults on the frost protection units)
- Accessories
- Warranty
- Transport
- Storage
- Installing the unit (only for experts)
- Preparing the installation place
- Unpack the equipment
- Aligning the unit and installing it
- Assemble the installation parts
- Water connection
- Electrical connection
- Fuel pipe to the external fuel tank
- Connect the washing station heater and start it up
- Check oil level
- Filling in detergents
- Initial startup
- Turning the base exchanger on
- Start-up of the RO plant
- Check the pressure of rim cleaner (option)
- Check the function of the system
- Starting up the gas burner (option)
- Dimension drawing for CAB model
- Dimension drawing for SKID model
- Dimension drawing for SKID model with WSO upgrade kit
- EU Declaration of Conformity
- Log of high pressure testing
- 22
Washing station 3 and 4 not shown.
1 Burner inclusive flow-type heater
2 Circulation pump for warm water
3 Balancing vessel
4 Swimmer tank for warm water
5 Safety valve
6 Locking valve of feeder pipe
7 Pipes of washing place heating
8 Thermostat mixing valve
9 Heat exchanger
10 Locking valve for filling pipe
11 Circulation pump for washing place
heating
– Opens when the permissible operating
pressure is exceeded - also even the le-
ver for hand-spray gun is released and
circulates the water. The high-pressure
jet is available when the hand-spray
gun is opened again.
The overflow valve is set by the manufac-
turer and sealed. Setting only by customer
service.
– The safety valve protects the heating
circuit of washing place heating (option)
against excess pressure.
– Regulates the feed temperature for the
washing place heating (option) depend-
ing on the return flow temperature.
If the burner does not ignite or the flame ex-
tinguishes during operation, then the flame
monitor closes the fuel solenoid valve and
switches off the burner blower.
– If the exhaust temperature exceeds the
permissible value, then the exhaust
thermostat automatically switches off
the burner and locks it.
– If the water temperature in the swimmer
tank for warm water falls when hot wa-
ter is removed and cold water flows in,
the tempreature sensor of the warm wa-
ter circulation pump switches on and
switches off again when the maximum
temperature is reached.
– Prevents the formation of steam in the
boiler.
– The flow monitor switches on the burner
after the warm water circulation pump
has been started.
– Switches off the burner if there is very
little water in the warm water swimmer
tank.
– The motor protection switch interrupts
the electric circuit if the motor is over-
loaded.
SB MB standard:
If the residual hardness of the softened wa-
ter exceeds a marginal value, the control
will calculate the residual capacity of the
base exchanger cylinder.
At the latest in the following night, the re-
generation of the base exchanger bottle is
started.
SB MB comfort:
If the residual hardness of the softened wa-
ter exceeds a limit value, the regeneration
of the base exchanger bottle begins imme-
diately.
If there is no water, the plant is stopped in
order to prevent dry running of the pump.
Switches off the pump when the buffer tank
for permeate is full.
Switches on the RO pump to produce per-
meate.
Emits a signal to the system when the per-
meate buffer tank is empty.
Prevents the externally added water over
60°C from being led to the HP pumps and
damaging them.
In case of a malfunction, the system switch-
es to an alternative water type (is set by the
service technician upon initial startup).
Washing place heating (option)
Monitoring and safety devices
Overflow valve of high-pressure pump
Safety valve
Thermostat mixing valve
Flame monitoring
Exhaust thermostat
Temperature controller
Temperature controller
Flow monitor
Water shortage safeguard
Motor protection switch
Hard water sensor
Pressure switch for RO water shortage
Level switch Buffer tank is full
Level sensor pump RO on
Level switch Buffer tank is empty
Temperature limiter 4. type of water /
warm (option)
24 EN