Operating instructions
Table Of Contents
- Contents
- About this operating instructions manual
- Environmental protection
- Safety instructions
- Operation
- Open the system
- Settings
- Main switch
- Adjust compressor
- Setting dosing pumps
- Dry foam station
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Blending device (option)
- Controls
- SB MB standard
- SB MB comfort
- Normal operation
- Open the menu "customer settings"
- Select the parameter you want to set
- Set the parameter with a variable
- Setting a parameter with several variables
- Exiting the menu
- Operating times
- Lighting time
- Fixed holidays
- Non-fixed holidays
- Date / Time
- Coin value
- Programme run times
- System settings
- Setting the dosing pumps
- System
- Hot blowers
- Washing station heater
- Frost protection with lost water
- Emergency frost protection
- External thermostat
- Filling in detergents
- Manual interventions
- Sales indicator
- Frost protection
- Shutting down
- Shutdown
- Function
- Flowchart system with wet foam
- Flowchart system with dry foam
- Attachment kit disconnection from mains (optional)
- Wheel cleaner/intensive foam (option)
- Micro emulsion (option)
- Frost protection 1-tool (option, SB- MB 2 pump Fp only)
- Frost protection 2-tool, wet foam (option, SB-MB 2 pump Fp only)
- 4. Type of water
- Internal frost protection (optional)
- External frost protection (optional)
- Washing place heating (option)
- Monitoring and safety devices
- Overflow valve of high-pressure pump
- Safety valve
- Thermostat mixing valve
- Flame monitoring
- Exhaust thermostat
- Temperature controller
- Temperature controller
- Flow monitor
- Water shortage safeguard
- Motor protection switch
- Hard water sensor
- Pressure switch for RO water shortage
- Level switch Buffer tank is full
- Level sensor pump RO on
- Level switch Buffer tank is empty
- Temperature limiter 4. type of water / warm (option)
- Technical specifications
- Maintenance and care
- Troubleshooting
- Who may remedy faults?
- Fault indication
- Faults shown in the display
- Acknowledge the faults
- Viewing the list of faults
- Viewing the event list
- Interruptions in warm water circulation
- Malfunctions of the washing station heater
- Burner malfunctions with oil-heated devices
- Burner malfunctions with gas-heated devices
- Malfunctions at coin mechanism
- Faults on high pressure pumps
- Disturbed detergent supply
- Malfunctions on the wheel cleaner/intensive foam
- Faults in the compressor
- Faults at the dry foam production (option)
- Interruptions in water preparation
- Faults on the frost protection units)
- Accessories
- Warranty
- Transport
- Storage
- Installing the unit (only for experts)
- Preparing the installation place
- Unpack the equipment
- Aligning the unit and installing it
- Assemble the installation parts
- Water connection
- Electrical connection
- Fuel pipe to the external fuel tank
- Connect the washing station heater and start it up
- Check oil level
- Filling in detergents
- Initial startup
- Turning the base exchanger on
- Start-up of the RO plant
- Check the pressure of rim cleaner (option)
- Check the function of the system
- Starting up the gas burner (option)
- Dimension drawing for CAB model
- Dimension drawing for SKID model
- Dimension drawing for SKID model with WSO upgrade kit
- EU Declaration of Conformity
- Log of high pressure testing
- 13
Note:
The pre-requisites for frost protection are:
– The main switch must be in position 1.
– The doors of the system must be
closed.
– Uninterrupted power, water and fuel
supply must be ensured.
– Water supply must also be protected
against freezing.
– The fuel supply must be protected
against frost (e.g. heating cartridge in
the tank, trace heating),
– Instructions for assembling and installa-
tion are given in chapter "Installing the
plant".
– The hot air ventilators have been set
correctly.
– All maintenance steps according to
"Maintenance and Care" have been
carried out correctly.
– All cleaning tools are placed back in the
storage compartment.
– The trigger guns with frost protection
holes that are part of the system are in-
stalled.
Note:
The washing place heating can function
properly provided the washing area has
been built properly according to the
KÄRCHER recommendations.
The heating power is sufficient for a heated
washing station surface of 50/60* m
2
. If the
heated surface exceeds this value, the frost
protection cannot be guaranteed.
Snow layers and large volumes of ice piec-
es fallen from the vehicles require a very
high heating capacity. It is necessary to re-
move these deposits.
* 50 m
2
with gas burner (67 kW); 60 m
2
with
oil burner (72 kW); with 4 high-pressure
modules type 908 the washing station sur-
face must be further reduced.
Before the onset of the frost period,
maintenance tasks must be carried out
"every year before the onset of the forst
period" according to section "Mainte-
nance and Care".
Carry out the following tasks for keep-
ing the frost protection intact.
Note:
Maintenance not being done on time or
from experts will mean, that there is no
guarantee concerning frost damage.
1 Locking valve 1 Throttle with sieve (marked red), 1-tool-
model
1 Filter for frost-protection pump
Washing station heater Maintenance jobs before and during
the frost period
Time Activity Assembly affected Performance By whom
many times
daily
opinion Washing brush Check for dirt and ice formation; lock foam wash if needed. Operator
daily Clean the
filter
Filter for frost-protection
pump
Clean the filter and replace Operator
opinion Hot blowers Are the hot air ventilators working (even for ABS fuel tank, option)? Operator
Recirculation blower Check function. Operator
Initially daily,
later on based
on experience
opinion Filling level of the fuel tank Will the heating oil be sufficient till next inspection? Take into ac-
count increased consumption due to anti-frost equipment. Insuffi-
cient fuel can lead to failure and damage to the system.
Operator
weekly opinion Heating ABS heating oil
tank (option)
With temperatures below 3°C, check if the trace heating of the heat-
ing oil line between the heating oil tank and SB MB is warm.
Operator
monthly or af-
ter 200 oper-
ating hours;
more fre-
quently if
needed
opinion Quantity of frost water pro-
tection in the frost protec-
tion circuit
Target value: approx. 0.5 l/min per washing tool
Water quantity is higher: Change the node piece in the hand-spray
gun.
몇 WARNING
Risk of injury and damage. If the frost protection water volume is big-
ger than the admissible value, the cleaning tool may move uncon-
trollably due to the exiting water stream. If the frost protection water
volume is too big, replace the union piece in the trigger gun by all
means.
Water quantity is lesser Clean filter for frost protection pump; clean
sieve in throttle, clean pipes, check the rotation direction of the
pump.
Operator
15EN