Operating instructions
Table Of Contents
- English
- Contents
- Environmental protection
- Danger or hazard levels
- Device elements
- Symbols on the machine
- Proper use
- Safety instructions
- Safety Devices
- Start up
- GFCI INSTRUCTIONS
- Operation
- Open/close the hood
- Opening/closing the trigger gun
- Replace the nozzle
- Operating modes
- Turning on the Appliance
- Interrupting operation
- Select spray type
- Operation with detergent
- Cleaning
- Operating with cold water
- Operating with hot water
- After operation with detergent
- Turn off the appliance
- Storing the Appliance
- Frost protection
- Shutdown
- Storage
- Transport
- Care and maintenance
- Troubleshooting
- Appliance is not running
- Device is not building up pressure
- Device continuously turns on and off while hand spray gun is open
- Device turns on and off while hand spray gun is closed
- Device leaks, water drips from the bottom of the device
- Device is not sucking in detergent
- Burner does not start
- Customer Service
- Warranty
- Accessories and Spare Parts
- Technical specifications
- Français
- Table des matières
- Protection de l’environnement
- Niveaux de danger
- Éléments de l'appareil
- Symboles sur l'appareil
- Utilisation conforme
- Consignes de sécurité
- Dispositifs de sécurité
- Mise en service
- DISJONCTEUR DIFFERENTIEL
- Utilisation
- Ouvrir/fermer le capot de l'appareil
- Ouvrir/fermer le pistolet de pulvérisation à main
- Remplacer la buse
- Modes de fonctionnement
- Mettre l'appareil en marche
- Interrompre le fonctionnement
- Choisir le type de jet
- Fonctionnement avec détergent
- Nettoyage
- Utilisation avec de l'eau froide
- Utilisation avec de l'eau chaude
- Après utilisation avec un détergent
- Mise hors service de l'appareil
- Ranger l’appareil
- Protection antigel
- Remisage
- Entreposage
- Transport
- Entretien et maintenance
- Assistance en cas de panne
- L'appareil ne fonctionne pas
- L'appareil n'établit aucune pression
- Lorsque la poignée-pistolet est ouverte, l'appareil ne cesse de se mettre sous et hors tension
- Lorsque la poignée-pistolet est fermée, l'appareil ne cesse de se mettre sous et hors tension
- L'appareil présente un fuit, de l'eau s'écoule de l'appareil par le bas
- L'appareil n'aspire pas de détergent
- Le brûleur ne s'allume pas
- Service après-vente
- Garantie
- Accessoires et pièces de rechange
- Caractéristiques techniques
- Español
- Índice de contenidos
- Protección del medio ambiente
- Niveles de peligro
- Elementos del aparato
- Símbolos en el aparato
- Uso previsto
- Indicaciones de seguridad
- Dispositivos de seguridad
- Puesta en marcha
- Instrucciones del Interruptor de Circuito de Avería por Puesta a Tierra
- Manejo
- Abrir/cerrar capó del aparato
- Abrir/cerrar la pistola pulverizadora
- Cambiar las boquillas
- Tipos de servicio
- Conexión del aparato
- Interrupción del funcionamiento
- Selección del tipo de chorro
- Funcionamiento con detergente
- Limpieza
- Servicio con agua fría
- Servicio con agua caliente
- Después del funcionamiento con detergente
- Desconexión del aparato
- Almacenamiento del aparato
- Protección antiheladas
- Parada
- Almacenamiento
- Transporte
- Cuidados y mantenimiento
- Ayuda en caso de avería
- El aparato no funciona
- El aparato no genera presión
- El aparato se apaga/enciende continuamente cuando la pistola está abierta
- El aparato se enciende y se apaga continuamente cuando la pistola está cerrada
- El aparato tiene fugas, el agua gotea del aparato por abajo
- El aparato no succiona detergente
- El quemador no se enciende
- Servicio de atención al cliente
- Garantía
- Accesorios y piezas de repuesto
- Datos técnicos
– If the operator is not fluent in English,
the manufacturer’s instructions and
warnings shall be read to and dis-
cussed with the operator in the opera-
tor’s native language by the purchaser/
owner, making sure that the operator
comprehends its contents.
– Owner and/or user must study and
maintain for future reference the manu-
facturers’ instructions.
This product must be grounded. If it should
malfunction or breakdown, grounding pro-
vides a path of least resistance for electric
current to reduce the risk of electric shock.
This product is equipped with a cord having
an equipment-grounding conductor and a
grounding plug. The plug must be plugged
into an appropriate outlet that is properly in-
stalled and grounded in accordance with all
local codes and ordinances.
DANGER
Improper connection of the equipment-
grounding conductor can result in a risk of
electrocution. Check with a qualified electri-
cian or service personnel if you are in doubt
as to whether the outlet is properly ground-
ed. Do not modify the plug provided with
the product - if it will not fit the outlet, have
a proper outlet installed by a qualified elec-
trician. Do not use any type of adapter with
this product.
This product is supplied with a Ground
Fault Circuit Interrupter (GFCI) built into the
power cord plug. This device provides addi-
tional protection from the risk of electric
shock. If power is interrupted in the line, the
GFCI will automatically re-close the circuit
to the load after power is restored. Depend-
ing on the GFCI model, it may be neces-
sary to manually operate the reset button to
restore power to the GFCI load circuit. If re-
placement of the plug or cord is needed use
identical replacement parts.
몇 CAUTION
When connecting the water inlet to the wa-
ter supply mains, local regulations of your
water company must be observed. In some
areas the unit must not be connected di-
rectly to the public drinking water supply.
This is to ensure that there is no feedback
of chemicals into the water supply. Direct
connection via a receiver tank or backflow
preventer, for example, is permitted.
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Dirt in the feed water will damage the unit.
To avoid this risk, we recommend fitting a
water filter.
– Garden hose must be at least 1/2 inch
in diameter.
– Flow rate of water supply must not fall
below 2.5 GPM (gallons per minute).
– Flow rate can be determined by running
the water for one minute into an empty
5-gallon container.
– The water supply temperature must not
exceed 86°F/30°C.
– Never use the pressure washer to draw
in water contaminated with solvents,
e.g. paint thinners, gasoline, oil, etc.
– Always prevent debris from being
drawn into the unit by using a clean wa-
ter source. Use additional water filter.
SAVE THESE INSTRUCTIONS!
GROUNDING INSTRUCTIONS
GROUND FAULT CIRCUIT
INTERRUPTER PROTECTION
WATER SUPPLY
5EN