Operating instructions
Table Of Contents
- English
- Contents
- Environmental protection
- Danger or hazard levels
- Device elements
- Symbols on the machine
- Proper use
- Safety instructions
- Safety Devices
- Start up
- GFCI INSTRUCTIONS
- Operation
- Open/close the hood
- Opening/closing the trigger gun
- Replace the nozzle
- Operating modes
- Turning on the Appliance
- Interrupting operation
- Select spray type
- Operation with detergent
- Cleaning
- Operating with cold water
- Operating with hot water
- After operation with detergent
- Turn off the appliance
- Storing the Appliance
- Frost protection
- Shutdown
- Storage
- Transport
- Care and maintenance
- Troubleshooting
- Appliance is not running
- Device is not building up pressure
- Device continuously turns on and off while hand spray gun is open
- Device turns on and off while hand spray gun is closed
- Device leaks, water drips from the bottom of the device
- Device is not sucking in detergent
- Burner does not start
- Customer Service
- Warranty
- Accessories and Spare Parts
- Technical specifications
- Français
- Table des matières
- Protection de l’environnement
- Niveaux de danger
- Éléments de l'appareil
- Symboles sur l'appareil
- Utilisation conforme
- Consignes de sécurité
- Dispositifs de sécurité
- Mise en service
- DISJONCTEUR DIFFERENTIEL
- Utilisation
- Ouvrir/fermer le capot de l'appareil
- Ouvrir/fermer le pistolet de pulvérisation à main
- Remplacer la buse
- Modes de fonctionnement
- Mettre l'appareil en marche
- Interrompre le fonctionnement
- Choisir le type de jet
- Fonctionnement avec détergent
- Nettoyage
- Utilisation avec de l'eau froide
- Utilisation avec de l'eau chaude
- Après utilisation avec un détergent
- Mise hors service de l'appareil
- Ranger l’appareil
- Protection antigel
- Remisage
- Entreposage
- Transport
- Entretien et maintenance
- Assistance en cas de panne
- L'appareil ne fonctionne pas
- L'appareil n'établit aucune pression
- Lorsque la poignée-pistolet est ouverte, l'appareil ne cesse de se mettre sous et hors tension
- Lorsque la poignée-pistolet est fermée, l'appareil ne cesse de se mettre sous et hors tension
- L'appareil présente un fuit, de l'eau s'écoule de l'appareil par le bas
- L'appareil n'aspire pas de détergent
- Le brûleur ne s'allume pas
- Service après-vente
- Garantie
- Accessoires et pièces de rechange
- Caractéristiques techniques
- Español
- Índice de contenidos
- Protección del medio ambiente
- Niveles de peligro
- Elementos del aparato
- Símbolos en el aparato
- Uso previsto
- Indicaciones de seguridad
- Dispositivos de seguridad
- Puesta en marcha
- Instrucciones del Interruptor de Circuito de Avería por Puesta a Tierra
- Manejo
- Abrir/cerrar capó del aparato
- Abrir/cerrar la pistola pulverizadora
- Cambiar las boquillas
- Tipos de servicio
- Conexión del aparato
- Interrupción del funcionamiento
- Selección del tipo de chorro
- Funcionamiento con detergente
- Limpieza
- Servicio con agua fría
- Servicio con agua caliente
- Después del funcionamiento con detergente
- Desconexión del aparato
- Almacenamiento del aparato
- Protección antiheladas
- Parada
- Almacenamiento
- Transporte
- Cuidados y mantenimiento
- Ayuda en caso de avería
- El aparato no funciona
- El aparato no genera presión
- El aparato se apaga/enciende continuamente cuando la pistola está abierta
- El aparato se enciende y se apaga continuamente cuando la pistola está cerrada
- El aparato tiene fugas, el agua gotea del aparato por abajo
- El aparato no succiona detergente
- El quemador no se enciende
- Servicio de atención al cliente
- Garantía
- Accesorios y piezas de repuesto
- Datos técnicos
– 8
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Clean filter in the water connection.
Clean filter at the detergent suck hose.
Have the maintenance of the device
performed by the customer service.
Note: It is not necessary to perform an oil
change on the high-pressure pump.
Remove the filter.
Clean filter in water and reinstall.
Clean filter in water and reinstall.
DANGER
Risk of injury by inadvertent start-up of ap-
pliance and electric shock. Prior to all work
on the appliance, switch off the appliance
and pull the power plug.
– No power
Check power connection/conduit.
– Engine overload/overheat
Set the appliance switch to "0/OFF“.
Allow device to cool down.
Turn on the appliance.
If malfunction still occurs, have device
checked by customer service.
– The exhaust temperature limiter has
been triggered, heating coil is sooted.
Have device de-sooted by customer
service.
– The exhaust temperature limiter has
been triggered, exhaust temperature
too high.
Set the appliance switch to "0/OFF“.
Allow device to cool down.
Only in devices with manual reset:
Illustration
Press reset button of the exhaust tem-
perature limiter.
Turn on the appliance.
If malfunction still occurs, have device
checked by customer service.
– Air within the system
Vent pump:
With open hand spray gun turn device
on and off multiple times with the device
switch.
Note: By dismantling the spray lance from
the hand spray gun, the venting process is
accelerated.
Fill/replace external detergent contain-
er if empty.
Check connections and conduits.
– Filter in the water connection is dirty
Clean filter.
– Amount of water supply is too low.
Check water supply level (refer to tech-
nical data).
– Water tap is closed.
Open tap.
– Air within the system
Vent pump:
With open hand spray gun turn device
on and off multiple times with the device
switch.
Note: By dismantling the spray lance from
the hand spray gun, the venting process is
accelerated.
– High-pressure nozzle clogged
Clean the nozzle.
Safety inspection/ maintenance
contract
Maintenance intervals
Weekly
Monthly
Every 500 operating hours, at least
annually
Maintenance Works
Clean filter in the water connection.
Clean filter at the detergent suck hose
Troubleshooting
Appliance is not running
Device is not building up pressure
Device continuously turns on and
off while hand spray gun is open
13EN