14.9.2 Password for Operation
Figure 53 TestGen2: password for operation
Password sets the password for the tag operation in the hexadecimal format
14.9.3 Write EPC
In this tab, it is possible to change the EPC of the tag.
Figure 54 TestGen2: write EPC
New EPC enters an EPC in the hexadecimal format
Make sure to comply with the maximum EPC length supported by the
tag. If the maximum length is exceeded, the tag will return an error.
Auto
increment
activates or deactivates increasing the EPC by one with each successful writing
process
Write EPC
to selected
tag
writes the EPC on the selected tag
Write EPC
to tag in
field
writes the EPC entered in 1 to a single tag
Ź When using this command, make sure there is only one tag in the field. Otherwise,