14.8.4 Select Filter Settings
By means of these settings, it is possible to filter certain tags, e.g. to only read tags with the defined data in
the respective memory banks. It is possible to set up to 32 filters.
Figure 49 Expert settings 2: select filter settings
Filter selects a filter
Target selects the tag target session
Ź Make sure the target matches the session set in Figure 46.
Action selects the action; see also EPCglobal Gen 2 Specification (p. 73)
Tipp
Ź To see the description of an action, hover over the Action field.
ۆ The description of the action appears in the tooltip:
Memory
bank
selects the memory bank (RFU/EPC/TID/User)
Save
select filter
data to file
saves the select filter data to file
Load select
filter data
to file
loads the select filter data from file
On activates or deactivates the select filter
Bit pointer sets from which memory address the filter compares the mask data
Mask
length
sets the mask length (0–255)
ᬎ
Mask data sets the data to be filtered
ᬏ
Get
reads the data of the filter selected at
ᬐ
Set sets the select filter
Tipp
In SRU-8X1X readers, select filter data are permanently stored in the reader, e.g. if the
select filter has been activated, it is active after a reader restart.