14.8.2 Copy Parameter Set
The Copy parameter set allows one parameter set to be copied into another.
Source
parameter set
selects the parameter set to be copied
Target
parameter set
selects the parameter set into which the source parameter set is to be copied
Copy copies the parameter set
Ź Click Copy.
ۆ On successful completion of the copy operation, the Copy button briefly glows
green and a corresponding message is displayed in the status field.
ۆ If there is an error, the Copy button glows red, an error pop-up message
appears and a warning is shown in the status field.
shows the progress of the copying process
14.8.3 Change Reader Parameter
Change reader parameter allows to change all reader settings using their respective configuration IDs.
Figure 48 Expert settings 2: change reader parameter
Parameter
ID
selects the parameter ID
Parameter
value
shows or sets the parameter value
The value is either decimal or hexadecimal, it is possible to switch between dec and
hex.
Active
parameter
set
shows the current active parameter set
Get
reads the value of the current parameter set of the reader and shows it at
Set