User's Manual
User Manual | SRU-8X1X RFID Reader 18000-63
Doc No. 47000001740
|
Version 01
|
2018-12-11
|
released
Page 83 of 105
Confidential
ᬎ
Gain selects the antenna gain between –32.00 dBiC and 31.75 dBiC
ᬏ
ERP/EIRP switches between ERP and EIRP
ᬐ
Port selects the antenna port or deactivates it
If the antenna is not activated, the system proceeds to the next antenna in the
Port Multiplex Configuration.
Ź For more details, refer to the Chapter MultiplexingAntennaport1...8 in the
Reader Configuration Manual for SRU-8X1X RFID Reader 18000-63.
ᬑ
Exposure time
specifies the exposure time on the antenna; only used for asynchronous
operation
Ź For more details, refer to the Chapter MultiplexingExposureTime1...8 in the
Configuration Manual for SRU-8X1X RFID Reader 18000-63.
ᬒ
Communication
Standard
selects a country-specific communication standard; the device version
determines which communication standard is permitted
ᬓ
Communication
Profile
selects the profile for the data rate and read reliability
This option allows the technician to directly influence the performance of the
reader and the spectrum of the signal. The profile names contain basic
orientation on the transmission and reception data rates.
ᬔ
Available
channels
(only available for
ETSI-readers)
selects the channel for the reader to use
Depending on the region, the reader transmits in the frequency range 865–868
MHz for Europe or 902–928 MHz for USA/Canada.
In Europe, the number of channels to be used can be limited. For this reason, it
is necessary to check the related check box for each channel the reader is to
use. This way, it is possible to avoid using specific channels on which there is
interference.
ᬕ
Initial Q
reflects the number of tags expected in the field; see also Chapter InitialQ in
Reader Configuration Manual
ᬖ
Sel
specifies whether other parameters are of interest for an inventory of the tag
population or not; see also Chapter QuerySel in Configuration Manual for
SRU-8X1X RFID Reader 18000-63
ᬗ
Session
sets which session the reader is to work with; see also Chapter Sessions in
Reader Configuration Manual
ᬘ
Target
specifies which tags in the population should take part in the inventory; see also
Chapter QueryTarget in Configuration Manual for SRU-8X1X RFID Reader
18000-63
To operate the reader in accordance with the related national standards, it is necessary to
take into account the antenna gain and the cable attenuation in the transmission power
setting.
Ź Do not exceed the permitted transmission power. Failure to observe this instruction can
result in non-compliant operation of the reader leading the termination of the type
approval.