ץSaves the settings that have been made as the settings for the selected application
in the selected parameter set. The ReaderStart SW resets the settings to the
factory settings first, thus overwriting the previous configuration.
If the settings have been reset, the Apply settings button briefly glows green and a
success message is displayed in the Status field of the ReaderStart SW interface.
If case of a fault, the Apply settings button briefly glows orange to indicate a
warning or red to indicate an error. If the fault has been caused by a missing entry,
the field lacking the entry also glows red. A warning/error description is displayed
in the Status field.
After the settings have been loaded, it is possible to go to the Basic reading tab
and to start the read process.
ᬇ
Settings of
selected
application
shows the settings that have been made for the selected application in the selected
parameter set
ᬈ
Properties
of selected
application
shows the properties of the selected application
Tipp
The read rate is influenced by many parameters. In addition to the selected broadcasting
profile with the respective data rates, there are also application-specific data, e.g. how many
tags the reader should expect in the field. You can optimize these parameters using the
Expert settings 1 and 2.
Ź If you are unsure whether the settings you have chosen are best suited for your
application, contact Kapsch support at ktc.office@kapsch.net (please refer to "Product