User Manual

Kapsch TrafficCom AG
Installation Manual | SRU-8100 RFID Reader 18000-63
Doc No. 47000001169 | Version 01 | 2014-11-03 | released
Page 53 of 58
7.6.1 Expert settings 2
The Expert settings 2 tab is split into four sections for further configuration of the reader device.
Figure 26 Expert settings 2 tab
The Default parameter set drop down menu allows configuration of the parameter set that is loaded from
the EEPROM into the RAM when the RFID reader device boots up.
The Copy parameter set section allows one parameter set to be copied into another. On successful
completion of the copy operation, the Copy button is lid green and a corresponding message is displayed in
the status window, otherwise the Copy button glows red.
The Change reader parameter section allows reader settings to be read or changed using their respective
configuration IDs. After selection of the parameter ID, the corresponding value of the current parameter set
of the reader device is read by clicking on Get parameter value and displayed in the field parameter value,
optionally as a decimal (dec) or hexadecimal (hex) value. A value that has already been read can be
converted to dec or hex by pressing the respective radio buttons. The Set parameter value button writes the
value stated in the Parameter value field into the reader device. The two actions (read and set) are shown
by the respective buttons glowing the respective color to indicate success and failure, and a message
appears in the status window accordingly.
In the Select settings area, filters can be set which are brought into effect by means of a “Select” command.
This offers the facility to filter out certain tags, or to detect only tags with certain defined data in the
respective memory banks. Up to 32 filters can be set in total. Successful reading of the values of the
selected filter and successful writing of the filter values is indicated by the respective button glowing green