created or edited manually, using a text editor. See [2]. In order to use the newly added actions in the
program, the file must be reloaded via the context menu.
The Actionlist must be selected from the drop-down list. The Button Add action writes the action list into
the reader. Pressing the Clear actionlist button clears down the selected list.
Note: When the action list has been created, it is assigned under the Assign input to Actionlist header to
an input and a selected signal edge. If it is desired to assign the list to both edges, the assignment must be
made once for the rising edge and once for the downward edge.
The assignment can be cancelled again by a restart/reset of the reader or by assignment of the No
Actionlist item.
The Actionlists created are stored only in the RAM of the reader. When restarting the reader these lists are
deleted. For usage within an operational application, the respective commands to program the actions lists
have to be executed by the host application on reader startup.
The basic I/O configuration is set within the communication tab (see Chapter 7.4.3):
Figure 24 GPIO settings in communication tab