User Manual

Kapsch TrafficCom AG
Installation Manual | SRU-8100 RFID Reader 18000-63
Doc No. 47000001169 | Version 01 | 2014-11-03 | released
Page 43 of 58
Note: The read rate is influenced by many parameters. These is, in addition to the selected regulatory profile
with the respective data rates, also application-specific data such as how many tags the reader is expecting
in the field. You can optimize these parameters using the expert settings tabs (see below). .
If the tags that have been read are to be saved to a file, this can be done by activating the Save to file
option. The EPC, the length of the EPC, the antenna on which the tag was read, the RSSI value together with
the time stamp when the tag was read are saved.
The data are then saved in a CSV file in the program’s working directory. In the File menu, you are able to
change this via “change to the log file File / Options / Path”
Once the mode and the parameters have been selected, the read process can be started. Both modes are
stopped by pressing the Stop button. The Delete button removes all tag entries from the table.
7.4.5 Basic writing function
The Basic writing tab allows easy writing on tags. A fundamental distinction is to be made between
synchronous writing - write on command - and asynchronous writing - write on arrival.
Figure 22 Basic write function tab
Synchronous writing:
In this type of writing the data can only be written selectively to one EPC. This is selected in the EPC combo
box in the center of the input window. Clicking the Refresh button detects once again all tags in the antenna
field and adds them to the combo box.