User Manual
Kapsch TrafficCom AG
Page 40 of 58
Installation Manual | SRU-8100 RFID Reader 18000-63
Doc No. 47000001169 | Version 01 | 2014-11-03 | released
47000001169-Ins-01
○ Application for detecting and writing on multiple tags in the antenna field, which are moving at more
than 14 m/s
○ the distance between the tags and the antenna should be less than a few meters
Shelf application
○ Application for detecting and writing on very many tags in the antenna field, which are not moving
○ the distance between the tags and the antenna should be less than 1 m
Place monitoring
○ Application for detecting multiple tags in the antenna field, which are moving at not more than 3 m/s
○ the distance between the tags and the antenna should be less than 1 m
If there are more applications than fit on the screen, the buttons alongside the applications are activated to
allow scrolling.
Clicking on the Apply settings button saves the settings that were made, as well as the settings for the
selected application in the selected parameter set. This is done by first resetting them to the factory settings
and thus overwriting the previous configuration. This must be acknowledged.
Success is indicated by the Apply settings button glowing briefly, and by display of a success message in
the status window. If the process fails, the button glows briefly orange for a warning or briefly red for an
error (and if the failure was due to an entry being omitted, in addition the field that is lacking the entry glows
red), and by display of a warning description or error description in the status window.
If the settings have been loaded successfully we may had on to the Basic reading tab.
Note: If more than one hundred tags simultaneously in the field, the application may be tuned with respect to:
When the max. read frequency option is set, on every detection (inventory) all tags are reset in order to read
them fresh. Under some circumstances the time allowed for detecting the tags may be insufficient, so that
some transponders are not detected. The tag frequency detection is thus increased.
When the max. read reliability option is set, tags that have already been read are not reset at every detection
(inventory), provided they are still being supplied with power. This means that only those tags which have not
yet been registered are detected. The confidence that all tags are read is thus increased.Basic read
functions
This index card is divided into two columns, the first column contains a table with information about the read
tags, and in the second column you can find the controls, which control the reading process.