User Manual
Kapsch TrafficCom AG
Installation Manual | SRU-8100 RFID Reader 18000-63
Doc No. 47000001169 | Version 01 | 2014-11-03 | released
Page 37 of 58
Note: If the output is not set to protocol access, it cannot be accessed when processing action lists. See the
GPIO functions section for more details on action lists.
Once all the settings have been performed, the changes are loaded to the reader by pressing the Save
changes button, and take effect immediately.
Default configuration: No default configuration is foreseen for this card type.
Note: If this card setting is changed from Auto detect or Card not used to GPIO, the reader must be
restarted so that the card is correctly initialized.
Ethernet settings:
Figure 19 Configuration parameters for the Ethernet module
The parameters have the following meaning:
Parameter Function
Name Here the host name of the reader which is logged on to the DNS server is stated. The
reader can be addressed by this name as an alternative to the IP address.
IP-Address For manual issuing of the address. This parameter can be used only if the DHCP is
deactivated
Subnetmask For manual issuing of a network mask. This parameter can be used only if the DHCP is
deactivated.
Gateway Manual input of IP default gateway. This parameter can be used only if DHCP is
deactivated.