User's Manual

1000005508-Bed-02
Fault Diagnosis
Problem
Cause
Repair
Power LED (green)
isn´t illuminated
Power supply plug from
the external power
supply is not connected
to a live AC outlet
Connect the power supply
plug from the external power
supply to a live AC outlet.
Power supply cable from
the external power
supply is not connected
to the OPS
Connect the power supply
cable from the external power
supply to the power connector
on the OPS
Fuse is blown
Contact the Sales or Service
Organization of
Kapsch TrafficCom
Programming LED
(orange) isn´t
illuminated
Lid of the OPS is open
Close the lid of the OPS
Programming LED
(orange) isn´t
illuminated
OPS software driver is
not installed correctly
Install or reinstall the
KAPSCH software package
OPS doesn´t
communicate with
the Point-of-Sale
Terminal
Ethernet cable is not
connected properly or
Ethernet cable is defect
Connect the Ethernet cable
correctly
OPS doesn´t
communicate with
the Point-of-Sale
Terminal
OPS software driver is
not installed correctly
Install or reinstall the
KAPSCH software package
Error LED (red)
flashes
General error
Contact the Sales or Service
Organization of
Kapsch TrafficCom