Technical Manual | WAVE Transceiver with precise localization capability MTX-9450 and TRX-9450 Page 9 of 26
1000005502-THb-02
Safety Instructions
Caution: The TCM/TIM overvoltage protection module must be used.
Caution: Cables shall not be bent to a smaller radius than specified by
the cable manufacturer. For cables listed in this manual the bent radius
shall be larger than 5 inch (12cm)
Caution: It is necessary to connect the device to ground with a low
impedance connection.
This reminder is provided to call the systems installer's attention to
Section 820.93 of the NFPA 70® National Electrical Code ® 2008
Edition, which provide guidelines for proper grounding and, in
particular, specify that the coaxial cable shield shall be connected to the
grounding system of the building, as close to the point of cable entry as
practical.
Maintenance Instructions
The Localization Transceivers MTX-9450 and TRX-9450 need no regular
electrical maintenance.
Inspection Instructions
Warning: Regular inspection of installed equipment is mandatory and
shall be in accordance with the local safety regulations for equipment
installed on the roadside.
Overvoltage
Protection
Handling of Cables
Grounding
Note to GPS System
Installer